All installations and services must be performed by qualified service personnel.

III. FURNACE SPECIFICATIONS

MODEL

 

OME-72

 

Low Fire

High Fire1

HEAT INPUT RATE (BTUH)

70,000

 

85,000

HEATING CAPACITY (BTUH)

60,000

 

72,000

BURNER NOZZLE (GPH X

 

 

 

ANGLE, HOLLOW CONE)

0.50X80°A

0.60X80°A

OIL PUMP PRESSURE (PSIG)

 

120

 

VENT PIPE SIZE (INCHES)

 

4

 

DESIGN TEMPERATURE RISE (°F)

65

 

MINIMUM RETURN AIR TEMP. (°F)

50

 

SEASONAL EFFICIENCY

 

 

 

(AFUE2 *, %)

 

86

 

1Burner shipped with 0.60x80°A nozzle

2*AFUE - INCLUDES STEADY STATE THERMAL EFFICIENCY AND OFF CYCLE LOSSES.

ELECTRICAL RATINGS AND SETTINGS: ELECTRICAL SUPPLY: 120 VAC / 60HZ / 1 PHASE

MAXIMUM TIME DELAY TYPE FUSE OR HACR BREAKER RATING: 15 AMPS

TOTAL RATED CURRENT (AMPS): 10.3

NOMINAL HEAT ANTICIPATOR SETTING -- 0.2 mA

DIMENSIONS & WEIGHTS:

CABINET: WIDTH - 18 IN., DEPTH – 24-3/4 IN., HEIGHT - 57 IN.

NO.70 MOBILE HOME BASE: WIDTH - 18 5/16 IN., DEPTH - 24¼ IN., HEIGHT - 4 IN.

WARM AIR DUCT: WIDTH – 12 IN., DEPTH – 12 IN., HEIGHT - 14 ¼ IN.

COTTAGE BASE: WIDTH – 18 3/16 IN., DEPTH - 24¼ IN., HEIGHT – 14¾ IN.

FILTER QUANTITY & SIZE: (1) @ 18 IN. x 24 IN. x 1 IN. EA.

APPROXIMATE SHIPPING WEIGHT: 240 LBS.

 

BURNER DATA

 

OME-72

MANUFACTURER:

R.W. BECKETT CORP.

MODEL:

AFG

AIR TUBE LENGTH (IN.): 3

HEAD DESIGN:

F-3

REFRACTORY TYPE:

ISOFORM (SOFT FIBER)

OIL PUMP

 

PRESSURE (P.S.I.G.)

120

8

Page 10
Image 10
Thermo Products ome-72d36 service manual III. Furnace Specifications Model, Burner Data