III. FURNACE SPECIFICATIONS
MODEL |
|
| |
| Low Fire | High Fire1 | |
HEAT INPUT RATE (BTUH) | 70,000 |
| 85,000 |
HEATING CAPACITY (BTUH) | 60,000 |
| 72,000 |
BURNER NOZZLE (GPH X |
|
|
|
ANGLE, HOLLOW CONE) | 0.50X80°A | 0.60X80°A | |
OIL PUMP PRESSURE (PSIG) |
| 120 |
|
VENT PIPE SIZE (INCHES) |
| 4 |
|
DESIGN TEMPERATURE RISE (°F) | 65 |
| |
MINIMUM RETURN AIR TEMP. (°F) | 50 |
| |
SEASONAL EFFICIENCY |
|
|
|
(AFUE2 *, %) |
| 86 |
|
1Burner shipped with 0.60x80°A nozzle
2*AFUE - INCLUDES STEADY STATE THERMAL EFFICIENCY AND OFF CYCLE LOSSES.
ELECTRICAL RATINGS AND SETTINGS: ELECTRICAL SUPPLY: 120 VAC / 60HZ / 1 PHASE
MAXIMUM TIME DELAY TYPE FUSE OR HACR BREAKER RATING: 15 AMPS
TOTAL RATED CURRENT (AMPS): 10.3
NOMINAL HEAT ANTICIPATOR SETTING
DIMENSIONS & WEIGHTS:
CABINET: WIDTH - 18 IN., DEPTH –
NO.70 MOBILE HOME BASE: WIDTH - 18 5/16 IN., DEPTH - 24¼ IN., HEIGHT - 4 IN.
WARM AIR DUCT: WIDTH – 12 IN., DEPTH – 12 IN., HEIGHT - 14 ¼ IN.
COTTAGE BASE: WIDTH – 18 3/16 IN., DEPTH - 24¼ IN., HEIGHT – 14¾ IN.
FILTER QUANTITY & SIZE: (1) @ 18 IN. x 24 IN. x 1 IN. EA.
APPROXIMATE SHIPPING WEIGHT: 240 LBS.
| BURNER DATA |
| |
MANUFACTURER: | R.W. BECKETT CORP. |
MODEL: | AFG |
AIR TUBE LENGTH (IN.): 3 | |
HEAD DESIGN: | |
REFRACTORY TYPE: | ISOFORM (SOFT FIBER) |
OIL PUMP |
|
PRESSURE (P.S.I.G.) | 120 |
8