Manual background

X2! = Analog output polarity: 0 = H-/V- (default)

1 = H-/V+

2 = H+/V-

3 = H+/V+

X2@ = Analog output sync format: 0 = RGBHV (default)

1 = RGBS

2 = RGsB

3 = Y, R-Y, B-Y bi-level

4 = Y, R-Y, B-Y tri-level

X2# = User presets or PIP presets — 1 to 16

X2$ = Input presets — 1 to 128

X2% = On-screen menu time-out or screen saver sync timeout, (default = 3 seconds)/output sync time-out (default = 501 - never)

0 = OSD is never displayed/output sync is instantly disabled with no active input 1 to 500 in 1 second increments,

501 = OSD never times out, output sync is never disabled

X2^ = Executive mode status: 0 = Off/disable, (default)

1 = Exec mode 1 — Complete front panel lockout

2 = Exec mode 2 — Partial front panel lockout (only input selection, Auto-Image, and PIP/Swap are still available)

X2& = PIP window input selection: 0 to 4 (0 = off). (Input 5 is not available for PIP mode.)

X2* = Overscan (applied to SMPTE [NTSC, PAL, 480p, 576p, 720p, 1080i, 1080p] input rates): 0 = 0.0% (default for RGB/HDMI),

1 = 2.5% (default for YUV, RGBcvS, S-video, composite)

X2( = Aspect ratio:

1 = Fill: each input rate will automatically fill the entire output raster (default)

2 = Follow: each input rate will be displayed with its native aspect ratio

X3) = Screen saver mode:

1 = Black screen (default)

2 = Blue screen with OSD text

X3! = Video mute: 0 = off/disable

1 = on/enable (mute to black)

2 = mute output sync and video

X3@ = Auto-Image threshold value: 0 (black) though 100 (white), default = 25

X3# = HDCP status (valid only on HDMI/DVI outputs): 0 = No sink or source detected

1 = Sink or source detected with HDCP

2 = Sink or source detected but no HDCP is present

X3% = Video switching duration:

from 2 (0.2 sec) to 50 (5.0 sec). Default value is 3 or 0.3 sec

DVS 605 • SIS Communication and Control

38

Page 44
Image 44
Extron electronic manual DVS 605 SIS Communication and Control