Symbol Definitions

Symbol Definitions

• = Space

] = Carriage return with line feed

¦or} = Carriage return with no line feed

E or W = Escape

14, 24, 28 = Superscripts indicate the error message displayed if the command is entered incorrectly or with invalid parameters. See “Error Response References,” on page 35.

X! = Input selection, 1-5, (0 = current input — 0 is valid only for Input Config settings: 0 = main when PIP is disabled, 0 = PIP when PIP is enabled)

X@ = Output selection:

0 = All outputs (default)

1 = Analog (VGA, YUVp, HDTV)

2 = HDMI

3 = 3G/HD-SDI

4 = None

X# = Input video format:

 

 

0

= No signal detected (only valid for detected input format query, such as X!*\ or “ I”)

1

= RGB

5

= Composite video

2

= YUV auto

6

= DVI/HDMI (available only for inputs 3, 4, and 5)

3

= RGBcvS 7 = Auto detect (default for inputs 1 and 2)

4

= S-video

 

 

X$ = Horizontal/vertical start — 0 to 255 (default midpoint = 128)

X% = Pixel phase — 0 to 63 (default = 31)

X^ = Total pixels — ±512 of the default value

X& = Active pixels — ±512 of the default value

X* = Active lines — ±512 of the default value

X( = Enable/disable: 0 = Off/disable, 1 = On/enable

X1) = Input standard:

 

 

0

= No signal detected

3

= NTSC 4.43

1

= NTSC 3.85

4

= SECAM

2

= PAL

 

 

- = N/A (occurs when input is an active RBG, YUV auto [but not NTSC/PAL], or HDMI signal)

X1! = Internal temperature (in degrees Celsius)

X1@ = Unit name is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9),

and the minus sign/hyphen (-). The first character must be an alpha character. The last character must not be a minus. No blank or space characters are permitted, and no distinction is made between upper- and lowercase.

X1# = Horizontal and vertical frequencies (format is three-digit with single decimal and leading zeros for example, 075.3)

X1$ = Text label/preset name: up to 16 characters

Manual background NOTE: User and input presets saved without a name are saved with the default names

“User Preset xx” (for example, User preset 12) or “Input preset xxx” (for example, input preset 122).

X1% = Picture adjustment — 0 to 127 (default = 64)

X1^ = Horizontal and vertical position, ±11000, with leading “+” or “-”, for example “- 02040”