Advanced Configuration
The following flowchart provides an overview of the Advanced Configuration submenu The options are
ADVANCED Next
CONFIG
| Next | |
AUTO IMAGE | ||
| ||
IN#x Off |
|
Rotate either to turn Auto Image mode on or off.
ASPECT RATIO | Next | AUTO MEMORY | Next | |
IN#x | FILL |
| IN#x ON |
|
| Rotate either to select | Rotate either to |
| |
| aspect ratio mode. | turn auto memory | ||
|
|
| on or off. |
|
OVERSCAN |
| Next |
| ||
|
| |
|
|
Rotate either to set overscan value.
|
| Next | |
SWITCH TYPE | |||
|
| ||
DISSOLVE |
|
|
Rotate either to change switch type.
TEST PATTERN | Next |
COLOR BARS |
|
Rotate either to |
|
change test pattern.
OSD DURATION | Next | TEMPERATURE | Next | FACT. RESET |
125 SEC |
| 96 F 35 C |
| HOLD AUTO |
Rotate either to |
| Indicates internal temperature | Press and hold Auto button | |
set OSD duration. | (not adjustable). |
| to reset unit to factory settings. |
Figure 18. Advanced Configuration Menu
Aspect Ratio
Use either Adjust knob ([ {) to set the aspect ratio to Fill or Follow.
The aspect ratio setting is per input, and allows the user to select between each input signal filling the entire output raster (Fill - default setting), or for each input rate to be displayed with its native aspect ratio (Follow - 4:3, 5:4, 15:9, 16:9, 16:10) with the correct letter box or pillar box settings visible under the Image Size and Image Position Picture Controls.
When in the Fill mode, if an aspect ratio adjustment for a single input rate is desired, the correct size and center can be set up using Image Size and Image Position under Picture Controls, using one of the aspect ratio test patterns for a template. If auto memory is enabled, then these settings are saved and recalled the next time the signal is detected.
The DVS 605 clears the previous size and position settings whenever the aspect ratio setting for an input is adjusted.