Extron electronic DVS 605 Ethernet data port, Firmware version requests, Command, ASCII Telnet

Models: DVS 605

1 98
Download 98 pages 46.7 Kb
Page 62
Image 62
Command

SIS Command and Response Table for IP Control Port

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional Description

 

(host to processor)

(host to processor)

(processor to host)

 

Ethernet data port

Set current connection

E0*X12& TC}

W 0%2A X12& TC

Pti0*X12&]

port timeout

 

 

 

View current connection

E0TC}

W 0TC

X12&]

port timeout

 

 

 

Set global IP port timeout

E1*X12& TC}

W 1%2AX12&TC

Pti1*X12&]

View global IP port

E1TC}

W 1TC

X12&]

timeout

 

 

 

 

 

 

 

Firmware version requests

 

 

 

ASCII (Telnet) NOTE: An asterisk (*) after the version number indicates the version currently running. Caret (^) indicates bad checksum/invalid load. Question marks (?) indicate version not URL Encoded (Web) loaded.

Query firmware versionQ or 1QQ or 1QX13!]Show the scaler firmware version number (X13!) to two decimal places. Gives the number of the currently running version of the user-updatable firmware.

DVS 605 • SIS Communication and Control

Query verbose version

0Q

0Q

All responses

information

 

 

from 2Q-3Q-4Q]

Example:

1Q

1Q

1.01

Query bootstrap version

2Q

2Q

X13!]

Example:

2Q

2Q

0.06

Query factory firmware

3Q

3Q

X13!(plus web ver.-

version

 

 

desc-date/time)]

Example:

3Q

3Q

1.00(1.37-DVS 605

 

 

 

Series -Fri, 12 Aug

 

 

 

2012 03:28:10 GMT)

Show bootstrap, factory-installed, and updated firmware versions. (See 2Q, 3Q, and 4Q, below.)

The bootstrap firmware is not user- replaceable but you may need this information for troubleshooting.

Factory-installed firmware is not user replaceable. This firmware is the version the processor reverts to after a mode 1 reset (see “Operation” section).

In this example, the factory firmware version is 1.00, (the kernel version 1.37), for the DVS 605, dated 12 August, 2012.

56

Response NOTE: X12& = The number of seconds before timeout on the IP connection: (min. = 1; max. = 65000; default = 30 = 300 seconds) Ethernet data port X13! = Version number (listed to 2 decimal places)

Page 62
Image 62
Extron electronic DVS 605 Ethernet data port, Firmware version requests, Command, ASCII Telnet, URL Encoded Web, Response