CHAPTER 2: INSTALLATION

DEFINITY Communications System

 

7400B Data Module

Page 2-12

User’s Guide

 

 

INITIAL SYSTEM CHECKS This section describes procedures for initially checking out your hardware and any required software. It is assumed at this point that your hardware and data communications software have been properly installed and are ready for use.

Note: Data communications software is required only if you are using a PC as your terminal device. A dedicated data terminal does not need data communications software.

Power-Up Self-Test

When power is first applied to the 7400B Data Module, the unit

 

performs a self-test to determine that it is in working order. The

 

progression of the self-test is indicated by the sequential, left-to-right

 

lighting of the 10 front-panel LEDs.

 

If the self-test finds no problems, the LEDs labeled POWER/TEST and

 

TR will remain lit and all other LED lamps will go out.

 

Note: The operation of the LEDs described here assumes that the

 

factory-default options are still in effect. Once certain

 

options have been changed, the operation of the LEDs may

 

differ from this description.

 

Your 7400B Data Module is now installed and ready for data

 

communications operation.

IF YOU ARE USING A PC

 

Review the documentation for your PC and data communications

 

software. Be sure that you understand both well enough to get the

 

software running and place your PC in terminal mode.

 

Since there is such a diversity of functionality among the many

 

packages available, refer to the user’s manual of the software package

 

for specific details of its use. Appendix C, “Application Notes”

 

provides guidelines for using a few of the more popular packages with

 

the 7400B Data Module.

IF YOU ARE USING A

 

To determine whether your terminal is communicating with the 7400B

DEDICATED TERMINAL

Data Module, type the following command line:

 

AT [ Enter ]

 

Note: The two characters of the “AT” command prefix must be

 

typed as either both uppercase or both lowercase. That is,

 

you can type either at or AT, but At or aT will not

 

work.

 

If everything is operating properly, the command should appear on the

 

screen as you type it, and the 7400B Data Module should respond with

 

OK. Refer to Chapter 5,“Troubleshooting,” for help if you are not

 

getting these results.

Page 23
Image 23
Lucent Technologies 7400B manual Power-Up Self-Test, If YOU are Using a PC, Dedicated Terminal

7400B specifications

The Lucent Technologies 7400B is a notable entry in the landscape of telecommunications and networking technology, showcasing an innovative blend of features and capabilities that cater to the evolving demands of modern communication systems. Released as part of the company's broader portfolio aimed at enhancing network efficiency and reliability, the 7400B addresses the needs of both voice and data transmission organized around high-performance protocols.

One of the main features of the Lucent Technologies 7400B is its advanced signal processing capabilities. The device is built to handle a significant amount of bandwidth, making it suitable for high-capacity environments where data traffic can fluctuate dynamically. With its ability to support various signaling protocols, the 7400B is adept at integrating with existing infrastructure while providing the flexibility required to adopt emerging technologies.

The 7400B employs state-of-the-art voice encoding and compression techniques that optimize the quality of voice communications. This technology ensures clarity and minimizes latency, which is crucial for enterprises relying heavily on voice-over-IP (VoIP) applications and unified communications. The system supports multiple codecs, enabling it to seamlessly manage both traditional telephony and next-generation voice services.

In terms of reliability, the Lucent 7400B features robust redundancy protocols, ensuring continuous service availability even in the face of potential hardware failures or unexpected disruptions. It also includes built-in diagnostic tools that facilitate rapid troubleshooting, allowing technicians to identify and resolve issues efficiently. This focus on reliability makes the 7400B a preferred choice for critical business applications where downtime can lead to significant productivity losses.

The integration of advanced networking technologies such as Quality of Service (QoS) further enhances the performance of the 7400B. This capability ensures that high-priority applications receive the necessary bandwidth, maintaining optimal performance levels regardless of overall network traffic loads.

Moreover, the Lucent Technologies 7400B is designed with scalability in mind. Organizations can start with a basic configuration and expand their capacity as needed, thus ensuring that their investment remains relevant as their communication demands grow. This scalability is complemented by a user-friendly management interface, allowing network administrators to configure and monitor the system with ease.

In summary, the Lucent Technologies 7400B stands out for its advanced signal processing, voice encoding capabilities, reliability features, and scalability. These characteristics make it a vital component for any organization looking to enhance their telecommunications infrastructure and meet the increasingly complex communication needs of today’s digital landscape.