2Use a standard Telnet application to connect to the V6000 Embedded Telnet Server.

3Login using the username (‘Admin’) and password (‘Admin’).

To access the CLI via the RS-232 port, follow these 2 steps:

1Connect the V6000 RS-232 port (labeled I0I0), located on the CPU module of the V6000 front panel, to either COM1 or COM2 RS-232 communication port on your PC with the supplied RS-232 cable.

2Use serial communication software (e.g., HyperTerminalTM) to connect to the V6000.

Set your serial communication software to the following communications port settings:

ƒ Baud Rate: 115,200 bps

ƒ Data bits: 8

ƒ Parity: None

ƒ Stop bits: 1

ƒFlow control: Hardware

The CLI prompt is available immediately.

Assigning an IP Address

To assign an IP address via the CLI, follow these 4 steps:

1At the prompt type ‘conf’ and press enter; the configuration folder is accessed.

2To check the current network parameters, at the prompt, type ‘GCP IP’ and press enter; the current network settings are displayed.

3Change the network settings by typing: ‘SCP IP [ip_address] [subnet_mask]

[default_gateway]’ (e.g., ‘SCP IP 10.13.77.7 255.255.0.0 10.13.0.1’); the new settings take effect on-the-fly. Connectivity is active at the new IP address.

This command requires you to enter all three network parameters (each separated by a space).

4To save the configuration, at the prompt, type ‘SAR’ and press enter; the V6000 restarts with the new network settings.