3G Green Green Globe ZTS Series Accessory Definitions, Calibrate, Ctap, El/P, HT12

Models: ZTS Series

1 10
Download 10 pages 10.97 Kb
Page 5
Image 5
ZTS Series Accessory Definitions

ZTS Series Accessory Definitions

6P

Microprocessor activated test switch (Momentary)

6A

Hardwired test switch (Maintained)

6AP

Microprocessor activated test switch (Maintained)

6B

Hardwired test switch (Maintained Auto - Momentary Test) Key operated

6C

Hardwired test switch (Maintained Auto - Maintained Test) Key operated

A1

Auxiliary Contact S.P.D.T. - Normal (Source 1) Failure

A1E

Auxiliary Contact S.P.D.T. - Emergency (Source 2) Failure

A3

Auxiliary Contact - closed in emergency (source 2) Additional available (10 max.) on ZTS and need to be specified

A4

Auxiliary Contact - closed in normal (source 1) Additional available (10 max.) on ZTS and need to be specified

A62

Motor disconnect and staged restart (1 contact)

AB3

Auxiliary Contact - closed in bypass emergency (source 2) (S.P.D.T.) (Standard up to 400A) Additional available (10 max.) on ZTS and need to be specified

AB4

Auxiliary Contact - closed in bypass normal (source 1) (S.P.D.T.) (Standard up to 400A) Additional available (10 max.) on ZTS and need to be specified

B9

Battery charger (ships separate from ATS)- semi- float 5 amp (need to specify input/output voltage and type LA, N, FL)

Calibrate

Microprocessor activated calibration feature

CDP

Programmable exerciser daily, 7/14/28/365 days user-selectable, with or without load.

CDT

Exerciser no load timer. Increased functionality no longer requires a jumper.

CTAP

Chicago transfer alarm panel mounted in door of enclosure. Includes 3 aux. contacts and fuse.

DS

Disconnect Switch. Disconnects source voltage to transfer power panel

DT (Delayed Transition Only)

Time Delay from Neutral Switch position to Source 1 on retransfer

DW (Delayed Transition Only)

Time Delay from Neutral Switch position to Source 2 on retransfer

E

Engine Start Relay

EL/P

Event log of last 16 events

F

Fan contact, closed when engine runs.

HT(1)(2)

Heater and Thermostat 208/240V (1) 380/600V (2) mounted and interwired in enclosure. (requires larger enclosure for 40-200A)

K

Frequency Meter - Door mounted

K/P

Frequency Indication on the controller

L

LNP Center-off position LCD-Indicator Indicating LED lights:

L1 Indicates Switch in Source 2 position.

L2 Indicates Switch in Source 1 position.

L3 Indicates Source 1 available.

L4 Indicates Source 2 available.

M1

Single Phase Amp Meter

M2

Three Phase Amp Meter

M80

Digital Meter Measures and displays true RMS volts, amps and frequency in a three-phase power system.

M82

Digital Meter Includes M80 functions plus Watts, KVA, KVAR, PF, etc. w/Modbus RS485 port

M83

Digital Meter Includes M82 functions plus THD capability and Modbus RS485 port

M84

Digital Meter Includes M83 functions plus unbalance 128 samples/cycle data logging, waveform capture and sag/swell capture.

Page 5 PB-5066

Page 5
Image 5
3G Green Green Globe ZTS Series Accessory Definitions, Calibrate, Ctap, El/P, HT12, DT Delayed Transition Only