ZTS Series Accessory Definitions

M85

Digital Meter Includes M84 functions plus unbalance 256 samples/cycle data logging, waveform capture and sag/swell capture.

M86

Digital Meter Includes M85 functions plus large graphical screen display with Ethernet communications port.

N1

Running Time Indicator - Door mounted

N2

Operation Counter - Door Mounted

P1

Engine Start Timer (adjustable to 6 sec.)

P2

Engine Start Timer (adjustable to 300 sec.)

Q2

Peak shave/remote load test/area protection - Relay (S.P.D.T.) (Need to specify voltage - 120 VAC, 24 VAC, 24 VDC - 120V default standard)

Q3

Inhibit transfer to emergency (Source 2) (load add relay) - Relay (S.P.D.T.) (Need to specify voltage - 120 VAC, 24 VAC, 24 VDC - 120V default standard)

Q7

Inhibit transfer to normal (Source 1) - Relay (S.P.D.T.) (Need to specify voltage - 120 VAC, 24 VAC, 24 VDC - 120V default standard)

R1-1/R1-3

Over Voltage sensing for normal (Source 1) single (R1-1) or three (R1-3) phase

R15/R15D

Load Shed. Should Source 2 become overloaded, a signal can be given to switch to the dead

or Mid position.

R16

Phase rotation sensing of Normal (Source 1) and Emergency (Source 2)

R26/R26D

Interruptable Power Rate Provisions.

Allow transfer out of Source 1 position to Mid position or dead Source 2. Alarm and Pre-Signal circuit included. (Need to specify voltage - 120 VAC, 24 VAC, 24 VDC - 120V default standard)

R50

In Phase monitor between Normal (Source 1) and Emergency (Source 2) to allow transfer

S5P

Microprocessor activated auto/manual retransfer selector switch for trnsferring to Normal (Source 1) (includes microprocessor activated YN accessory)

S12P

Microprocessor activated auto/manual retransfer selector switch for trnsferring to Normal (Source 1) (includes microprocessor activated YN & YE accessory)

S13P

Microprocessor activated commit/no commit on transferring to Emergency (Source 2) (with enable/disable)

S14

Keyed selector switch for (retransfer to normal-test-auto)

SW1

Auto/Off/Start Engine control selector - Door mounted (keyed or non-keyed operation available)

SW2

Auto/Off Engine control selector - Door mounted (keyed or non-keyed operation available)

SW3

Source Priority Selector Switch - Door mounted Allows selection of Source 1 or Source 2 to be the Prime Source. Transfer Switch will transfer to selected Prime Source if that Source is available. (keyed or non-keyed operation available)

T

Retransfer to normal adjustable time delay

T3/W3

Pre-signal contact on transfer to Normal (Source 1) or Emergency (Source 2) during test.

U

Engine stop /cool adjustable cool down timer

UMD

Pre and ppost transfer output adjustable time range. Functions in both directions. Includes 2 circuits. Additional circuits available.

VI

Voltage imbalance between phases (3 Phase only)

W

Adjustabvle time delay on transfer to Emergency (Source 2)

YEN

Bypass transfer timers function (soft switch in control)

ZNET

Microprocessor Communication Module

PB-5066 Page 6

Page 6
Image 6
3G Green Green Globe ZTS Series specifications M85, M86, R1-1/R1-3, R15/R15D, R16, R26/R26D, R50, S12P, S13P, S14, T3/W3