Page 18
LOCATING EMS MARKERS
EMS markers may be detected and located using either the Dynatel
2205 or 2206 EMS Marker Locating Accessory. To attach the accessory,
slide the Receiver horizontally into EMS Marker Locating Accessory
mounting slot. Make sure the locking button holds the Receiver securely
in the slot. To separate the units, press the locking button down and slide
the Receiver out of the EMS Marker Locating Accessory mounting slot.
Press to turn the Receiver on.

Locating Markers while Tracing Cable Path

To detect markers while tracing the cable path, set the 2205 or 2206
accessory mode switch to the Alert position, and trace the cable path
normally. The internal buzzer in the accessory will alert you to the
proximity of a detected marker.
Note: Do not use Null or Differential modes when using the 2205 or 2206.

Locating Markers using the Receiver

If the buzzer response is too broad, the exact marker position may be
pinpointed by using the Receiver.
Select 577 Hz or 33 kHz on the Accessory. Use a different
frequency from the tracing signal.
Turn the Receiver ON, select Peak mode, and set the frequency to
match the Accessory setting.
Note: The initial Receiver gain in Peak mode is optimized for interfacing
with the 2205 or 2206 Accessory while searching for a marker. Press
only when a marker is detected and the signal is too strong. To search for
a new marker, reset the Receiver gain to the initial setting by turning its
power OFF and back ON, or pressing and then re-selecting the Peak
mode.
Refer to the EMS Marker Locating Accessory operating instructions for
further information.