LOCATING A BURIED CABLE
Transmitter Setup
Note: Key descriptions can be found inside the Transmitter lid.
Perform a battery test and then connect the Transmitter using one of the
three methods below to put tracing signal on a cable.
DANGER!
Voltage greater than 240 volts will damage equipment and cause
personal injury and death. Make all direct test connections before
turning on the Transmitter. Then activate the Transmitter in the Ohms
mode and check the display for voltage readings. Follow standard
procedures for reducing the voltage.
WARNING!
Potential for electrical shock exists when handling connecting cables
while the Transmitter is in the TRACE, FAULT or TONE modes. Turn
the Transmitter off before handling connecting cables.
Page 5