3M 2600 manual Note An optional 6 volt battery and cord are available

Models: 2600

1 20
Download 20 pages 41.65 Kb
Page 7
Image 7
Note: An optional 6 volt battery and cord are available.

4.04Connect the power cord from the AC adapter to the stripper handle. Plug the AC adapter into an electrical outlet.

Note: An optional 6 volt battery and cord are available.

4.05Arrange the fibers in the splice tray per tray instructions. Trim the ribbon end so that it extends approximately 3/4" (19 mm) beyond the center of the splice.

4.06Insert the ribbon into the tube guide and position the ribbon so that

1 1/4" to 1 1/2" (32 mm to 38 mm) of coating will be removed.

4.07Close the handle on the stripper. This will activate the heating unit which will soften the coating of the ribbon.

Note: The heating unit becomes hot. Use care when handling.

4.08Heat the coating until it softens (usually 8 to 10 seconds at room temperature). Slowly pull the ribbon straight out of the stripper. The handles should remain closed until the ribbon is completely out of the stripper.

Note: Do not keep the handles closed for more than 25 seconds or the heating unit may become damaged.

Note: Heating time will vary with fiber type and ambient temperature. If difficulty is experienced, refer to Section 12.