10.0 Splice Actuation

9.02Look at the amount of bare glass where each ribbon enters the splice. The amount of bare glass should be about the same on each side.

9.03If necessary, center the ribbons by selecting the pre-load lever that is closest to the shorter length of bare glass. Slowly slide the lever back (away from you) until the holders move and the ribbons appear centered.

NOT CENTERED

9.04Return the lever to its forward position. If the ribbon was adjusted too far, re-adjust using the other lever.

Note: Make sure both pre-load levers are all the way forward (toward you) when done.

10.0 Splice Actuation

10.01Actuate the splice by squeezing the actuation lever slowly until it stops.

10.02 Close both splice covers.

Note: Some protective gel may be visible after closing covers.