9.02Look at the amount of bare glass where each ribbon enters the splice. The amount of bare glass should be about the same on each side.
9.03If necessary, center the ribbons by selecting the
NOT CENTERED
9.04Return the lever to its forward position. If the ribbon was adjusted too far,
Note: Make sure both
10.0 Splice Actuation
10.01Actuate the splice by squeezing the actuation lever slowly until it stops.
10.02 Close both splice covers.
Note: Some protective gel may be visible after closing covers.
CENTERED
14