3M C1060 manual Replacing Battery Holder Parts, Service Procedures continued, Tools Required

Models: C1060

1 14
Download 14 pages 6.52 Kb
Page 13
Image 13
Replacing Battery Holder Parts

Model C1060 Headset Intercom System

Replacement Parts and Service

Service Procedures (continued)

Replacing Battery Holder Parts

Tools Required:

1 – Number 0 Phillips Screwdriver

1 – Soldering iron.

Procedures:

1.Make sure power is off and remove Battery.

2.Remove two screws and Cover. (If replacing old style Battery Contacts, discard all Battery Holder parts, they are not compatible with newer Battery Holder parts.)

3.Unsolder the two Battery Holder PWA wires.

4.Insert the Headband wires through the holes from the back side of the replacement Battery Holder PWA. Solder the RED wire to the + connection point and the BLACK wire to the

connection point.

5.Press the Battery Latch Spring onto the top peg of the Battery Latch. Insert the Latch with Spring down through the top of the Base as shown. The beveled bottom edge of the Latch MUST face the battery.

6.Press the top of the Spring into the small molded ribs located inside the top of the Base.

7.Insert the Battery Latch Button through the front of BOTH the Base and Latch. Squeeze the parts until they snap securely together.

8.Press the Battery Holder PWA onto the pegs of the Base noting that one hole is larger than the other.

9.Place the hole in the Headband over the retaining peg in the Cover. Route the power wires between the two posts near the top and the three posts near the bottom as shown. Be careful to avoid pinching wires while replacing Cover and two screws.

10.Install new Headband Pad on Battery Holder Cover.

Battery Latch

Button

Power Wire

Routing

Battery Latch

Spring

Battery Latch

Battery Holder PWA