3M Model D-2400

Component Placement

Component Placement

This section describes placement of the 3M™ Convenience Store Intercom System, Model D-2400, components:

Communications Controller

For proper system operation, locate the Communications Controller:

1.Near the conduit termination of the Call Station wiring.

2.Near the power source.

3.At least 10 feet away from electrical noise sources such as the following:

-large electrical motors (such as air conditioners, freezers, and coolers)

-any electrical components that arc (i.e., relays)

-ballasts (for light fixtures)

4.In a secure room away from traffic.

5.Approximately 5 feet above the floor.

6.Where it is accessible from the top, bottom, and both sides.

7.In a dry and heated (between 50° and 100° Fahrenheit) location.

See Figure 2.

Power Supply

Locate the power supply as follows:

1.Install the power supply mounting bracket in a preferred location, as shown in Figure 2.

2.Insert the power supply transformer into the mounting bracket, as shown in Figure 2.

Figure 2. Suggested Communications Controller Placement

3

Page 7
Image 7
3M D-2400 installation instructions Communications Controller, Power Supply