Programming the System

3M Model D-2400

07:Priority{Off} S=xx: User Name

08:Auto Standby

09:Station Name S=xy: User Name

10:Sync All Data ‘T A L K’ = Yes

Are You Sure ? ‘T A L K’ = Yes

11:Software Rev. Se=a.bc Con=x.yz

Re-Initializing the Selector

Initialize All ? ‘T A L K’ = Yes

A value (Off, 1 to 16 inclusive). Priority station #, always moves to top of queue.

On or Off. Enables the 30 second station connection time out. Default = On.

Assignment of station names 01 through Max Stations where xx indicates station #. Default = PUMP # xy, xy = station #.

Command to synchronize all Selectors with the data in the Controller and the Selector that issued the command.

This confirmation message follows the above. Selectors must be On Line to be synchronized.

Read from Selector & Controller. Selector and Controller software revision numbers.

To re-initialize the Selector to its original factory settings:

1.Remove Power to the Selector.

2.Press the ALL CALL key.

3.Apply Power to the Selector.

4.Release the ALL CALL key.

5.Confirm the re-initialize procedure by pressing the TALK key. (To abort, press the STD BY key.)

6.Remember to adjust all of the parameters so that the Selector functions properly in its given installation.

12

Page 16
Image 16