3M X75 The lens cap is attached, The signal cables are not correctly connected, and play monitor

Models: X75

1 57
Download 57 pages 23.1 Kb
Page 53
Image 53
The lens cap is attached.

Troubleshooting

Phenomena that may easily be mistaken for machine defects (continued)

Phenomenon

No pictures are displayed.

Cases not involving a machine defect

Reference

page

 

The lens cap is attached.

4, 16

Remove the lens cap

 

The signal cables are not correctly connected.

10, 11,

Correctly connect the connection cables.

12

The brightness is adjusted to an extremely low level.

 

Adjust the BRIGHT to a higher level using the menu function

24, 26

or the remote control

Colors have a

faded- out

appearance, or

Color tone is

poor.

The computer cannot detect the projector as a plug

 

and play monitor.

10,11,

Make sure that the computer’s can detect a plug and play

12

monitor using other plug and play monitor.

 

Color settings are not correctly adjusted.

 

Perform picture adjustments by changing the COLOR

24 , 27,

TEMP, COLOR TINT and/or COLOR SPAC E settings,

32

using the menu functions.

 

COLOR SPACE setting is not suitable.

 

Change the COLOR SPACE setting to AUTO, RGB,

32

SMPTE240, REC709 or REC601.

The brightness and/or contrast are adjusted to an extremely low level.

Adjust the BRIGHT and/or CONTRAST settings to a higher level using the menu function.

Pictures appear The WHISPER function is working.

dark. Select the NORMAL to the item WHISPER in the SETUP

menu.

24 , 26

24, 34

Pictures appear

blurry.

The lamp is approaching the end of its product lifetime.

Replace the lamp.

Either the focus and/or horizontal phase settings are not properly.

Adjust the focus using the focus ring , and/or H PHASE using the menu function.

The lens is dirty or misty.

Clean the lens by referring to the section “Caring for the

lens”.

44 , 45

18, 29

47

NOTE • Although bright spots or dark spots may appear on the screen, this is a unique characteristic of liquid crystal displays, and such do not constitute or imply a machine defect.