A.O. Smith ST 3000 Technical specifications, FOR THE INSTALLER 2.1Installation, Water connections

Models: ST 1500 ST 3000

1 12
Download 12 pages 3.56 Kb
Page 4
Image 4

1.4 Technical specifications

 

 

 

ST 1500/2000

ST 2500/3000

1

Storage capacity

ltr

1500/2000

2500/3000

2

Tank heat loss

kWh/24h

8.5

10.1

3

Maximum working pressure

bar

7

7

4

Test pressure tank

bar

12

12

5

Maximum allowed tank temperature

°C

95

95

6

Weight empty

kg

374/506

637/739

2. FOR THE INSTALLER

2.1Installation

A qualified, competent installer must install the hot water storage tanks in accordance with local valid regulations and codes.

Location needs to be chosen to prevent damage in case of tank leakage (e.g. place tank in a drain pan or near a floor drain of sufficient capacity). For mounting of the jacket see separate attached Kit installation sheet.

2.2 Water connections

The water heater is suitable for connection to vented, un-vented and pumped pressurized systems. In each case appropriate valves and fittings should be used to ensure the system complies with the governing codes and appropriate building requirements. The maximum working pressure is 7 bars. A typical installation diagram for an un-vented installation is as follows:

4

Page 4
Image 4
A.O. Smith ST 3000 Technical specifications, FOR THE INSTALLER 2.1Installation, Water connections, ST 1500/2000, 2500/3000