GB
802CC | 852CC |
Schleicher International
CLEANING THE PHOTOCELLS (8) (Fig. 4):
If paper particles should come to rest in the inlet guide (for example after a paper jam) it is possible that the machine will not turn off, due to the broken light barrier.
To remove these paper strips and also to clean the photocell, pass another sheet of paper through the feed slot, or switch the machine to reverse and wipe both „eyes“ of the photocell with a brush.
MAINTENANCE
8
CUTTING SYSTEM MAINTANANCE:
After about 2 hours of continuous operation run the cutting system in reverse for about 30 seconds and, at the same time, spray some of the enclosed special oil onto the cutting system.
ENERGY SAVING TIP:
Be certain that the machine is turned off overnight (mains switch (1) (fig. 1) switched to „0“).
fig. 4
MALFUNCTION |
| TECHNICAL DATA |
TAKING OUT EXCESS PAPER
IN CASE OF OVERLOAD:
If the shredder has stopped due to an overload (motor protection) take the excess paper out of the inlet as follows:
1.Depress the reverse pushbutton (4) (fig. 2). The material is released.
2.Lift up the hopper. The pilot lamp „door open“ or „hopper open“ (7) (fig. 2) will light.
3.Remove the excess material by hand from the inlet guide.
Note: In this case, there is no danger of injury as all circuits are interrupted when the hopper is lifted and the machine cannot be started.
MOTOR FAULT:
The machine is equipped with a thermally protected motor. Should this motor be overloaded, it will switch off automatically. In such case the pilot lamp „ready“ (5) (fig. 2) flashes.
After a cooling down period of approx. 10 minutes (depending on the room temperature) you can restart the machine and continue shredding.
Note: When the motor is overloaded, only the | Cutting width: |
| |
forward run is cut off. To take the excess paper out | 802CC: | 1.9x15 | |
of the inlet opening, the cutting system may at any | 852CC: | 3.8x40 | |
time be switched on „reverse“. | Cutting capacity: |
| |
|
| 802CC: | |
FAULT CHECKLIST: | 852CC: | ||
If the machine is not functioning properly, you | Working width: | 444 mm | |
should check the following: | Power: | 3.9 kW | |
- | is the plug conneted to the mains? | Supply voltage: | 400V/50Hz |
- | is the mains switch (1) turned on? |
| 230V/50Hz |
- | is the door closed? |
| 415V/50Hz |
- | is the collecting bag full? |
| 220V/60Hz |
| The bag has to be emptied. |
| 200V/50Hz |
- | is the motor overloaded? |
| 200V/60Hz |
| Please refer to the section headed „Motor Fault“. |
|
|
- | is there a phase failure? | (gl fuse, type 1 assignment) | |
| Check the | 16 A | |
| socket, and replace if necessary. | 25 A | |
|
| 25 A | |
If you still cannot isolate the fault after carrying | Width: | 750 mm | |
out all these checks, please notify our customer | Depht: | 550 mm | |
service department. | Height: |
| |
|
| 802CC: | 1275 mm |
|
| 852CC: | 1600 mm |
|
| Noise level: | approx. 75 dB(A) |
|
| Weight: |
|
|
| 802CC: | approx. 185 kg |
|
| 852CC: | approx. 201 kg |
ACCESSORIES
Description | |
Plastic bag, 600 x 380 x 1100 x 0,6 mm | 80946 |
Lubrication bottle, 125 ml | 99943 |
Note: For orders of special accessories and spare parts, please contact your dealer.