Accton Technology ES3628EA Optional Redundant Power Supply, Power Supply Receptacles, Condition

Models: ES3628EA

1 62
Download 62 pages 11.34 Kb
Page 20
Image 20
Figure 1-3 System LEDs

1 Introduction

System Indicators

Figure 1-3 System LEDs

Table 1-2 System Status LEDs

LED

Condition

Status

Power

On Green

Internal power is operating normally.

 

 

 

 

On Amber

Internal Power supply fault.

 

 

 

 

Off

Power off or failure.

 

 

 

Diag

Flashing Green

System self-diagnostic test in progress.

 

 

 

 

On Green

System self-diagnostic test successfully completed.

 

 

 

 

On Amber

System self-diagnostic test has detected a fault.

 

 

 

 

Alternating

Fan failure or system overheated.

 

Amber & Green

 

RPS

On Green

Redundant power supply is receiving power.

 

 

 

 

On Amber

Fault in redundant power supply (including thermal or fan).

 

 

 

 

Off

There is no redundant power supply currently attached.

 

 

 

Optional Redundant Power Supply

The switch supports an optional Redundant Power Supply (RPS) that can supply power to the switch if the internal power supply should fail.

Power Supply Receptacles

There are two power receptacles on the rear panel of the switch. The standard power receptacle is for the AC power cord. The receptacle labeled “RPS” is for the optional Redundant Power Supply (RPS).

Redundant Power Socket

Power Socket

RPS

 

DC 12V 13A

100-240V~

50-60Hz 0.6A

Figure 1-4 Power Supply Receptacles

1-4

Page 20
Image 20
Accton Technology ES3628EA Optional Redundant Power Supply, Power Supply Receptacles, 3 System LEDs -2 System Status LEDs