iii

Safety Compliance

Warning: Fiber Optic Port Safety

Avertissment: Ports pour fibres optiques - sécurité sur le plan optique

Warnhinweis: Faseroptikanschlüsse - Optische Sicherheit

Underwriters Laboratories Compliance Statement

Important! Before making connections, make sure you have the correct cord set. Check

it (read the label on the cable) against the following:

The unit automatically matches the connected input voltage. Therefore, no additional

adjustments are necessary when connecting it to any input voltage within the range

marked on the rear panel.

When using a fiber optic port, never look at the transmit laser while it is
powered on. Also, never look directly at the fiber TX port and fiber cable
ends when they are powered on.
Ne regardez jamais le laser tant qu'il est sous tension. Ne regardez
jamais directement le port TX (Transmission) à fibres optiques et les
embouts de câbles à fibres optiques tant qu'ils sont sous tension.
Niemals ein Übertragungslaser betrachten, während dieses
eingeschaltet ist. Niemals direkt auf den Faser-TX-Anschluß
und auf die Faserkabelenden schauen, während diese
eingeschaltet sind.
Operating Voltage Cord Set Specifications
120 Volts UL Listed/CSA Certified Cord Set
Minimum 18 AWG
Type SVT or SJT three conductor cord
Maximum length of 15 feet
Parallel blade, grounding type attachment plug rated 15 A, 125 V
240 Volts (Europe only) Cord Set with H05VV-F cord having three conductors with
minimum diameter of 0.75 mm2
IEC-320 receptacle
Male plug rated 10 A, 250 V