AC Adapter

Item

 

Specification

 

 

 

Output Ratings (CV mode)

 

 

 

 

DC output voltage

Offers constant voltage 19.0V output source with 90W max output power

 

capacity.

 

 

 

Noise + Ripple

300mvp-pmax (20MHz bandwidth) for resistor load

 

 

 

Output current

0 A (min.)

4.74A (max.)

 

 

 

Output Ratings (CC mode)

 

 

 

 

 

DC output voltage

19.0

 

 

 

 

Constant output

3.5A

 

 

 

 

Dynamic Output Characteristics

 

 

 

 

Start-up time

3 sec. (@115 Vac and 230Vac full load)

 

 

Hold up time

10ms min. (@115 Vac input, full load)

 

 

 

Over Voltage Protection (OVP)

26 V

 

 

 

Short circuit protection

Output can be shorted without damage, and auto recovery

 

 

Electrostatic discharge (ESD)

15kV (at air discharge)

 

8kV (at contact discharge)

 

 

 

Dielectric Withstand Voltage

 

 

 

 

Primary to secondary

4242 Vdc for 1 second

 

 

Leakage current

60uA at 254Vac

 

 

Regulatory Requirements

1. FCC class B requirements (USA)

 

2. VDE class B requirements (German)

 

3. VCCI classII requirements (Japan)

 

 

 

Power Management

ACPI Mode

Power Management

 

 

Mech. Off (G3)

All devices in the system are turned off completely.

 

 

Soft Off (G2/S5)

OS initiated shutdown. All devices in the system are turned off

 

completely.

 

 

Working (G0/S0)

Individual devices such as the CPU and hard disk may be power

 

managed in this state.

 

 

Sleeping State (S3)

CPU in Stop Clock state

 

VGA Suspend

 

PCMCIA Suspend

 

Audio Power Down

 

Hard Disk Power Down

 

Super I/O Low Power mode

 

 

Sleeping State (S4)

Also called Hibernate state. System saves all system states and

 

data onto the disk prior to power off the whole system.

 

 

Environmental Requirements

 

Item

Specification

 

 

 

 

 

 

Temperature

 

 

 

 

 

 

 

Operating

+5~+35°C

 

 

 

 

 

 

Non-operating

-20~+65°C

 

 

 

 

 

 

Non-operating

-20~+50°C (storage package)

 

 

 

 

 

 

Humidity

 

 

 

 

 

 

 

Operating

10% to 90% RH, non-condensing

 

 

 

 

 

 

Non-operating

10% to 90% RH, non-condensing (unpacked)

 

 

 

 

 

 

 

 

 

Chapter 1

33

Page 41
Image 41