Acer B203W manual Electrical Requirements, Standard Test Conditions, Measurement systems

Models: B203W

1 48
Download 48 pages 9.75 Kb
Page 8
Image 8

Electrical Requirements

Standard Test Conditions

All tests shall be performed under the following conditions, unless otherwise specified.

Ambient light

Dark room (< 1 cd/m2)

 

 

Viewing distance

40 cm for LCD performance, 20 cm for LCD failures

Warm up time

30 minutes

 

 

Analog Input signal

700 mVss

Control temperature

6500°K (e-Color set to “User” mode)

 

 

Brightness control

The value under user mode

 

Set to The value under user mode, which allows that the brightest

User contrast control

two of 32 linear distributed gray-scales (0700mv) can be

 

distinguished.

Picture position and size

Factory preset value

 

 

Viewing angle

90 ° H and V

AC Supply voltage

230V± 5, 50±3Hz

Ambient temperature

20+5

Humidity

65% ± 20%

Display mode

1680x1050, 60 Hz, all white

 

 

e-color mode

Set to “User” mode

Measurement systems

The units of measure stated in this document are listed below: 1 gamma = 1 nano tesla

1 tesla = 10,000 gauss cm = in x 2.54

Lb = kg x 2.2

Degrees F = [°C x 1.8] + 32 Degrees C = [°F - 32]/1.8 u' = 4x/(-2x + 12y + 3)

v' = 9y/(-2x + 12y + 3)

x = (27u'/4)/[(9u'/2) - 12v' + 9] y = (3v')/[(9u'/2) - 12v' + 9] nits = cd/(m2) = Ft-L x 3.426 lux = foot-candle x 10.76