AU OPTRONICS CORPORATION
Product Specification
document version 1.0 8
NUMPAGES
|
29
}
M240HW01 V2
Note 3: Contrast ratio is measured by TOPCON SR-3
Note 4: Definition of Response time measured by Westar TRD-100A
The output signals of photo detector are measured when the input signals are changed from “Full
Black” to “Full White” (rising time, TrR), and from “Full White” to “Full Black” (falling time, TfF),
respectively. The response time is interval between the 10% and 90% (1 frame at 60 Hz) of
amplitudes.
TrR + TfF = 5 msec (typ.).
Note 5: Color chromaticity and coordinates (CIE) is measured by TOPCON SR-3
Note 6: Central luminance is measured by TOPCON SR-3
Note 7: Luminance uniformity of these 9 points is defined as below and measured by
TOPCON SR-3
9)-(1 Points 9in LuminanceMaximum
9)-(1 points 9in LuminanceMinimum
Uniformity =
Note 8: Crosstalk is defined as below and measured by TOPCON SR-3
100
90
10
0
%
Optical
response White
TrFTrR
100
10
0
%
Optical
response White Black
TrFTrR
Black
1 Frame 1 Frame