7.1.3Non operation Thermal Shock Test

 

Item

 

Description

 

Temperature

 

-200C to 600C

 

Reset cycles times

 

25ºC>60ºC (10hrs)>25ºC (2hrs)>-20ºC(10hrs)>25ºC

 

 

3cycles ,every transition time 0.5 hr,

 

 

 

 

 

 

 

 

Total cycles

 

3 cycles

7.1.4Package Drop

Drop height (Select drop height according to the gross weight refer to the table at below)

 

 

Gross Weight(kg)

 

 

 

1.0<W9.0

 

 

 

 

 

 

 

 

 

 

 

Drop Height(cm)

 

 

 

76

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drop sequence and orientation

 

 

 

 

 

 

 

 

Drop

Drop onto

Type Drop

Figure

 

Step 1

Corner(2-3-5)of package

Corner

 

 

 

 

 

 

 

 

Step 2

Edge(3-5)

of package

Edge

 

 

 

 

 

 

 

 

Step 3

Edge(2-3)

of package

Edge

 

 

 

 

 

 

 

 

Step 4

Edge(2-5)

of package

Edge

 

 

 

 

 

 

 

Step 5

Face(bottom-3)of package

Flat

 

 

 

 

 

 

 

 

Step 6

Face(left-4)

of package

Flat

 

 

 

 

 

 

 

Step 7

Face(front-5) of package

Flat

 

 

 

 

 

 

 

Step 8

Face(right-2) of package

Flat

 

 

 

 

 

 

 

 

Step 9

Face(rear-6)

of package

Flat

 

 

 

 

 

 

 

 

Step 10

Face(Top-1)

of package

Flat

 

 

 

 

 

 

 

 

 

 

 

Mechanical and electrical damage should not exist after vibration test, and shall be submitted for approval customer before mass production.

8. Marking and Identification

8.1S/N Label

The approval marking is required by the countries of sales destination.

8.2 Carton label

The approval marking is required by the countries of sales destination.

Page 26
Image 26
Acer LCD-S243HL service manual 1S/N Label, Carton label