8.AIS alarm messages (NMEA 0183 ALR, Text)

Local alarm condition and status. This sentence is used to report an alarm condition on a device and its current state of acknowledgement.

ALR message format

!-- ALR,hhmmss.ss,xxx,A,A,c--c*hh<CR><LF> field 1 2 3 4 5

 

Field

 

 

Format

 

 

Description

 

 

 

 

 

 

 

1

 

x

 

 

hhmmss.ss = Time of alarm (UTC)

 

2

 

 

 

 

 

Unique alarm number

 

3

 

 

 

 

 

Alarm condition

 

4

 

 

 

 

 

Alarm acknowledge state

 

5

 

 

 

 

 

Alarm description, text

 

 

 

 

 

 

 

 

Alarm descriptions presented are:

 

 

 

 

 

 

 

 

AIS: TX malfunction

 

 

 

 

 

 

 

 

AIS: Antenna VSWR exceeds limit

 

 

 

 

 

 

 

 

AIS: Rx channel 1 malfunction

 

 

 

 

 

 

 

 

AIS: Rx channel 2 malfunction

 

 

 

 

 

 

 

 

AIS: general failure

 

 

 

 

 

 

 

 

AIS: no sensor position in use

 

 

 

 

 

 

 

 

AIS: no valid SOG information

 

 

 

 

 

 

 

 

AIS: no valid COG information

 

 

 

 

 

 

 

 

AIS: 12V alarm

 

 

 

 

 

 

 

 

AIS: 5V alarm

 

 

 

 

 

 

 

 

AIS: Loss of serial interface integrity

 

 

 

 

 

 

 

 

AIS: Background noise above -77dBm

 

9.ACK messages

An Acknowledge Message (ACK) can be generated by a minimum keypad and display (MKD) unit, chart plotter or other display device connected to the Nauticast™-B to acknowledge an alarm condition reported by the Nauticast™-B.

ACK message format

!-- ACK,xxx*hh <CR><LF> field 1

 

Field

 

 

Format

 

 

Description

 

 

 

 

 

 

 

1

 

x

 

 

unique alarm number

 

27

Y1-03-0222 Rev. C

Page 27
Image 27
ACR Electronics Y1-03-0222 AIS alarm messages Nmea 0183 ALR, Text, ACK messages, ALR message format, Format Description