Y1-06-0209G 13
SECTION 7 INSTALLING THE HRU IN AN OPEN FACED BRACKET
The ACR open faced bracket is a
discontinued product that looks like this:
Contents of the HydroFix™ HRU Kit that you will need:
HydroFix Replacement
Hydrostatic Release unit (E)
Open faced release rod (C)
2 Mounting bracket adapters (J)
Mounting rod adapter, metal (L)
Small cotter pin (G)
4 Mounting bracket screws (F)
HRU Expiration Label (K)
Slotted spring pin (I)
Tools required: Phillips-head screwdriver,
pliers
Instructions:
1.) Unscrew the four side screws removing the front cover from the
bottom mounting plate, keeping the screws.
2.) Unscrew the spring loaded HRU Rod from the bracket and remove
the expired HRU. Discard all HRU rods and components.
3.) Align mounting bracket adapters (J) with the screw holes on the
bottom mounting plate (see Figure A).
4.) Using the 4 screws removed from the front cover; loosely attach
mounting bracket adapters (J) to the bottom mounting plate. Some
adjustments may be needed to align the brack et screw holes with
the screw holes on the bottom mounting plate.
5.) Mark the expiry date on the HRU according t o the i nstructions in
Section 3.