Y1-06-0209G 9
SECTION 5 INSTALLING THE HRU IN A SeaShelter2 BRACKET
The following ACR EPIRBs are compatible with
the SeaShelter2 (ACR P/N 9435/9455):
GlobalFix 406
RapidFix 406
SATELLITE2 406
SATELLITE 406™ (discontinued
product)
Contents of the HydroFix™ HRU Kit that you will need:
HydroFix Replacement
Hydrostatic Release Unit (E)
SeaShelter release rod (A)
Keyed bracket adapter (D)
Large cotter pin (H)
HRU expiration label (K)
Instructions:
1.) Remove the front cover of the brack et and carefully release the
EPIRB from the bracket.
2.) Remove the old HRU unit and rod from the
bracket by pressing the spring release back
and sliding the old HRU up and out of the
bracket.
3.) Take the SeaShelter2 release rod (A) and
place it on top of the rod on the HRU,
aligning the two sets of holes on the base
(see Figure A).
4.) Place large cotter pin (H) inside the two
holes, securing the two rods together.
5.) Place keyed bracket adapter (D) on the bottom of the HRU. This
part is keyed so that it will fit together only one way. Turn to the right
until it snaps into place.
6.) Mark the expiry date on the HRU according to the instructions in
Section 3.
7.) Record the expiration date on the HRU expira tion label (K) with an
indelible marker.
Figure A