ADCP-50-404 • Issue 2 • November 1998

Ripple voltage* is held to the following limits:

+5 Vdc, at or below 50 Millivolts, Peak-to-Peak +12 Vdc, at or below 120 Millivolts, Peak-to-Peak –12 Vdc, at or below 120 Millivolts, Peak-to-Peak

*Measured with a device having a 50 MHz bandwidth.

4.SPECIFICATIONS

PARAMETER

SPECIFICATION

 

 

Input

 

Voltage

190/240 Vac

Current

2 Amps Maximum (4 Modules)

Frequency

48 to 62 Hz

Fusing (On rear of basic unit)

220 Vac: 4-Amp, Dual, Time Delay

 

 

Output Each Module

 

Voltage

+5 Vdc ± 5%

 

+12 Vdc ± 10%

 

–12 Vdc ± 10%

Current

4.5 Amp DC Max. @ +5 V

 

1.0 Amp DC Max. @ +12 V

 

0.5 Amp DC Max. @ –12 V

 

 

Physical

 

Chassis

3.5 ￿ 19 ￿ 11 inches (8.9 ￿ 48.3 ￿ 27.94 cm)

Expansion Module

3.5 ￿ 3.9 ￿ 9.22 inches (8.9 ￿ 9.91 ￿ 23.5 cm)

 

 

Environmental

 

Operating Temperature

0￿ to 50￿ C (32￿ to 122￿ F)

Storage Temperature

–40 ￿ to +70￿ C (–40 ￿ to 158￿ F)

Operating Humidity

10 to 80% non-condensing

Storage Humidity

5 to 90% non-condensing

Electromagnetic Compatibility

Meets CISPR22 Class B radiated and conducted emissions.

 

 

Page 4