ADCP-50-404 • Issue 2 • November 1998
5. OUTPUT CABLE ASSIGNMENTS
Output from the DMPS-l0CE Power Supply is delivered via a 6 foot, 16 gauge cable, terminated in a 9-pin connector. Pin assignments on the connector are as follows:
Pin 1 | — | +5 Volts | Pin 6 | — | Earth Ground |
Pin 2 — | +5 Volts | Pin 7 | — Common Ground for +5 and ± 12 V |
Pin 3 | — | +12 Volts | Pin 8 | — Common Ground for +5 and ± 12 V |
Pin 4 | — | No Connection | Pin 9 | — | –12 Volts |
Pin 5 | — | No Connection | | | |
See Figure 3 for sketch of the 9-pin connector.
6
39
4555-A
Figure 3. 9-Pin Connector
6. INSTALLATION
6.1 DMPS-10CE Power Supply Installation
Remove each item from its shipping container and inspect the units for signs of damage. If there are any damaged or missing parts, immediately file a claim with the commercial common carrier or its agent, and notify ADC Telecommunications, Inc.
Normally, the ADC DMPS-10CE Power Supply is shipped with the standard single power unit installed. Additional DMPS-10EXP/CE expansion modules are shipped in separate containers. Occasionally, a power supply may be shipped with expansion modules installed. In either case, installation of the power supply involves positioning the unit in the desired rack space, near an ac utility outlet, and securing it with the mounting hardware normally used on the mounting rack.
Note: The DMPS-10CE Power Supply requires air for convection cooling. Air holes in the top cover and bottom cover allow air to flow through the power supply chassis. For this reason, be sure to mount the DMPS-10CE Power Supply in such a fashion as to leave at least half of the top and bottom surfaces open to air movement.
Page 5
© 1998, ADC Telecommunications, Inc.