(e)Install the two screws removed in step (b) above to hold the expansion module in place.
(f)Connect the output power cable to the unit requiring the dc power. Pin
Note: It is recommended that the
8. POWER-UP OF THE DMPS-10CE POWER SUPPLY
The
(a)Turn the power switch located on the front panel to the OFF (“0”) position.
(b)Connect the 220 Vac power cord provided to the power supply shelf.
(c)Cut the plug off the other end of the power cord. Replace the plug with a plug that matches your utility outlet.
(d)Connect the other end of the power cord to the utility outlet.
(e)Set the ac switch at the front of the
(f)Verify that power LED is lit on the front of the power supply for the basic power supply and any expansion modules installed.
9.REPLACING THE LINE FUSE
The line fuses are located in dual
(a)Set the ac switch to OFF (“0”) position.
(b)Remove the line cord from its utility outlet.
(c)Disconnect the line cord from the socket in back of the
(d)Turn fuse holder carrier in a
(e)Use an Ohm meter to check fuses for opens.
(f)Replace the bad fuse/fuses and reinsert the fuse carrier back into its socket. Turn fuse carrier clockwise until fully seated.
(g)Repeat Steps d – f for the other fuse.
(h)Reconnect the power cord to the Power Supply and its utility outlet.
(i)Set the ac switch to ON (“ I”) position.
Page 7
© 1998, ADC Telecommunications, Inc.