Steam Requirements – High Pressure

Operating Steam Pressure

Maximum

150 psig*

 

1.0 MPa

Heat Input (Normal Load)

 

5 Bhp

Consumption (Approximate)

167 lb/hr

 

75.74 kg/hr

Inlet / Return

3/4” / 3/4”

Shaded areas are stated in metric equivalents

*The minimum operating pressure for optimum results is 100 psig (689.47 kPa).

Installation Instructions

To ensure an adequate supply of steam is provided, be sure that the steam supply lines and steam return lines are sized and laid out as stipulated in this manual. Inadequate steam supply lines and steam return lines or improper steam plumbing will result in poor performance and can cause component failure. Clean, dry steam must be provided to the dryer.

Important: Steam coil failure due to water hammer by wet steam will void the warranty.

The presence of condensate in the steam supply line will cause water hammer and subsequent heat exchanger (steam coil) failure. The steam supply connection into the main supply line must be made with a minimum 10-inch (25.4 cm) riser. This will prevent any condensate from draining towards the dryer.

The steam supply line to the dryer must include a 12-inch (30.48 cm) riser along with a drip trap and check valve. This will prevent any condensate from entering the steam coil.

Flexible hoses or couplings must be used. The dryer vibrates slightly when it runs and this will cause the steam coil connections to crack if they are hard piped to the supply and return mains.

Shutoff valves for each dryer should be installed in the supply line, return line, and drip trap return line. This will allow the dryer to be isolated from the supply main and the return main if the dryer needs maintenance work.

Install an inverted bucket steam trap and check valve at least 12-inches (30.48 cm) below the steam coil as close to the coil as possible. A trap with a minimum capacity of 272 lb (123.37 kg) of condensate per hour at 125 psi (8.62 bar) is needed for each unit. (Based on 2 times the steam consumption per hour.)

The supply line and the return line should be insulated. This will save energy and provide for the safety of the operator and maintenance personnel.

Water pockets in the supply line, caused by low points, will provide wet steam to the coil possibly causing steam coil damage. All horizontal runs of steam supply piping should be pitched 1/4-inch (6.35 mm) for every 1 foot (0.31 meters) back towards the steam supply header causing the condensate in the line to drain to the header. Install a bypass trap in any low point to eliminate wet steam.

Important: Flexible hoses/couplings must be used. Coil failure due to hard plumbing connections will void the warranty.

Water Information ____________________

Before You Start

Check Local Codes and Permits

Call your local water company or the proper municipal authority for information regarding local codes.

Important: It is your responsibility to have all plumbing connections made by a qualified professional to ensure that the plumbing installation is adequate and conforms to local, state, and federal regulations or codes.

It is the installer’s or owner’s responsibility to see that the required water pressure, pipe size, or connections are provided. The manufacturer assumes no responsibility if the fire suppression system is not connected, installed, or maintained properly.

Installation

Water Supply

The fire suppression system must be supplied with a minimum water pipe size of 1/2-inch (12.7 mm) and be provided with 40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) of pressure.

If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold/freezing temperatures, provisions must be made to protect these water lines from freezing.

Warning

!If the water in the supply line or water solenoid valve freezes, the fire suppression system will

be inoperative!!

Water Connections

The water connection is made to the 3/4”-11.5 NH hose adaptor, which is shipped in the tumbler and must be installed to the 1/2” N.P.T. water connection, located at the upper rear of the dryer. A flexible supply line/coupling must be used in an effort to avoid damaging the electric water solenoid valve.

Note: The 3/4”-11.5 NH is a standard hose coupling screw thread. It is not to be confused with 3/4” N.P.T. The sealing of an NH connection is made with a washer opposed to the mating threads of an N.P.T. assembly. The 2 thread designs are not compatible.

It is recommended that a filter or strainer be installed in the water supply line.

Important: Flexible supply line/coupling must be used. Solenoid valve failure due to hard plumbing connections will void warranty.

The dryer is to be connected to the water mains using a new hose set and the old hose set should not be reused.

Electrical Requirements

No independent external power source or supply connection is necessary. The 24-volt power to operate the fire suppression system is accomplished internally in the dryer (from the dryer controls).

16

American Dryer Corp.

113615 -2

Page 16
Image 16
ADC HBG76 manual Water Information

HBG76 specifications

The ADC HBG76 is a state-of-the-art device designed for high-performance data acquisition and processing. It is primarily aimed at various applications in industries such as telecommunications, aerospace, military, and industrial automation. The HBG76's advanced features, robust technologies, and exceptional characteristics make it a standout choice for professionals requiring precise and reliable data handling.

One of the hallmark features of the HBG76 is its high-speed sampling capabilities. The ADC can handle sample rates exceeding 1 GSPS (giga samples per second), enabling it to capture rapid signal dynamics with exceptional fidelity. This capability is particularly valuable in applications where timing is crucial, such as radar systems or high-frequency trading in finance.

The HBG76 incorporates cutting-edge analog-to-digital conversion technology, ensuring that the signal integrity is maintained throughout the conversion process. With a resolution of up to 16 bits, the ADC delivers impressive accuracy and detail, facilitating high-quality signal representation. This feature is essential for applications requiring precise measurement and analysis of data.

Another significant aspect of the HBG76 is its versatility in connectivity options. The device supports various communication interfaces, including USB, Ethernet, and SPI, making it compatible with a wide range of systems. This flexibility allows users to integrate the ADC seamlessly into existing hardware setups, enhancing overall efficiency and ease of use.

In terms of power efficiency, the HBG76 is designed with advanced low-power technologies that optimize its energy consumption without compromising performance. This feature is particularly beneficial for battery-operated devices and remote applications where power availability may be limited.

The robust design of the HBG76 ensures longevity and reliability in demanding environments. Its rugged casing provides protection against dust, moisture, and temperature extremes, making it suitable for outdoor use and harsh industrial settings.

Overall, the ADC HBG76 stands out as a powerful tool for data acquisition and processing, boasting high-speed sampling, excellent resolution, versatile connectivity, energy efficiency, and durability. Whether in research laboratories, industrial monitoring, or advanced telecommunications systems, the HBG76 is engineered to meet the evolving needs of modern applications, driving innovation across diverse sectors.