GFA-6002 Specifications
Power Rating (To IEC/CEA-490A Requirements)
70 Watts continuous average power into 8 ohms at any frequency between 20Hz and 20kHz with all channels driven at less than 1.0% THD.
100 Watts continuous average power into 4 ohms at any frequency between 20Hz and 20kHz with all channels driven at less than 1.0% THD.
Bridged Power: 175 Watts continuous average power (one channel) into 8 ohms at any frequency between 20Hz and 20kHz with at less than 1.0% THD.
IM Distortion (SMPTE)
1 watt to 70 watts into 8 ohms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≤ 0.05%
IM Distortion (CCIF, Any Combination from 4kHz to 20kHz)
70 watts into 8 ohms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≤ 0.01%
Frequency Response @ 1 Watt into 8 Ohms
10Hz to 20kHz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +0,
Power Bandwidth
Dynamic Headroom Into 4 Ohms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.8 dB
Signal to Noise Ratio, “A” Weighted
70 watts into 8 ohms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≥ 100dB
Gain. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29dB
Input Sensitivity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . variable
Input impedance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17k ohms
Damping Factor
2OHz to 2OkHz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≥ 400
Rise Time
5kHz, 90V,
Power Consumption (Continuous, All Channels Driven)
Quiescent. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30VA Maximum. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600VA
General
Power (available in 230VAC by special order). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .