ELECTRICAL SPECIFICATIONS

WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 8

ELECTRICAL SPECIFICATIONS

1.All wiring must comply with local and national electrical codes and must be installed by a licensed electrician. If you have any questions regarding the following instructions, contact a licensed electrician.

2.Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.

3.For your safety and protection, this unit is grounded through the power cord when plugged into a matching wall outlet. If you are not sure whether your wall outlet is properly grounded, please consult a licensed electrician.

4.The wall outlet (3-pin) must match the plug

(3-pin) on the power cord supplied with the unit. DO NOT use plug adapters or extension cords. See (Table 1) for receptacle and fuse information.

5.The rating plate on the unit contains electrical and other technical data. The rating plate is located on the front of the base pan. Make sure to use the correct power supply according to the rating plate of your air conditioner.

Electric Shock Hazard

!

 

 

If the air conditioner has a serial plate rating of 115 volts and up to and including 7.5 amps, the unit maybe on a fuse or circuit breaker with other devices. However, the maximum amps on all devices for that fuse or circuit breaker can not exceed the amps of the fuse for the circuit breaker.

If the air conditioner has a serial plate rating of 115 volts and greater than 7.5 amps it must have its own fuse or circuit breaker, and no other device or unit should be operated on the fuse or circuit breaker.

If the air conditioner has a serial plate rating of 230 volts, it must have its own fuse or circuit breaker, and no other device or unit should be operated on the fuse or circuit breaker.

To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing.

RECEPTACLE AND FUSE TYPES

COOLING CAPACITY

8K-15K

18K

22K-24K

 

 

 

 

 

 

 

RATED VOLTS

125

 

250

250

 

 

 

 

 

 

 

 

 

 

 

AMPS

15

 

15

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WALL OUTLET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSE SIZE

15

15

20

Note:8K-15K including AAW-08CM1FHUE AAW-08CR1FHUE

Table 1

 

AAW-10CM1FHUE AAW-10CR1FHUE

 

AAW-12CM1FHUE AAW-12CR1FHUE

 

AAW-15CM1FHUE AAW-15CR1FHUE

 

18K including AAW-18CR3FHUE AAW-18CM3FHUE

 

22K-24K including AAW-22CR3FHUE AAW-22CM3FHUE

 

AAW-24CR3FHUE AAW-24CM3FHUE

 