– 10 –
)XQFWLRQVRIWKH7RXFKSDGV

NOTE: The functions printed directly on the keys

indicate their primary purpose (most require entry of
a security code first); the functions printed under
some keys (shown in brackets in the list below)
indicate an alternate function available on voice
touchpads only.
1. DISPLAY WINDOW.
Custom English Display Touchpads: 2-line, 32-
character Liquid Crystal Display (LCD) touchpads
that display protection point identification, system
status, and messages.
English Display Touchpads: Display protection
zone ID and system status messages using pre-
designated words in the LCD display.
2. 1 OFF Disarms burglary portion of the system,
silences alarms and audible trouble indicators,
and clears visual display after problem's
correction.
[RECORD] Used to record up to a 2.5-minute
message.
3. 2 AWAY Arms the entire burglary system,
perimeter and interior.
[VOLUME] Used with the desired [3] or [6] keys
to set playback and system announcement volume.

4. 3 STAY Arms perimeter portion of burglary

system only. Interior protection is not armed,
allowing movement within premises without
causing an alarm.
[PLAY] Used to playback a recorded message.
[] Used with VOLUME key to raise volume.
5. 4 This is not a Function key. Used only as
a numeric key.
6.5 TEST Tests the system and alarm sounder if
disarmed. Refer to Testing The System section for
test procedures.
7. 6 BYPASS Re moves individual protection zones
from being monitored by the system.
[]Used with VOLUME key to lowe r volume.

8. 7INSTANT Arms in manner similar to the STAY

mode, but without the entry delay feature.
Entering via an entry/exit door will cause an
instant alarm.

9. 8 CODE Used to assign additional user codes

for other users of the system.
10. 9 CHIME Turns CHIME mode on and off.
When on, the opening of windows or doors while
the system is disarmed will sound 3 beeps at the
touchpad(s).
11. # This key can be used for "Quick Arming" of
the system without use of a
security code (if programmed).
[FUNCTION] Used to enable voice and volume
functions.
12. Key 0 [VOICE] Used to activate the
RECORD, VOLUME, and PLAY functions.
13. READY Used to display all open protection
zones.
[STATUS] Used to announce system status and
faulted zones (if any exist).

14. KEYS 0–9: Numeric keys used to enter your

security code(s).

15. MIC: Microphone for Message Center recordings.

16. MESSAGE LED: (red). Flashes red when

message waiting or lights steady red when
recording a message.

17. READY INDICATOR: (green) Lit when the

system is ready to be armed (no faults present).
While the system is disarmed, this indicator will
go on and off as protection zones are closed and
opened.

18. ARMED INDICATOR: (red) Lit when the

system has been armed.
19. FUNCTION KEYS: Keys A, B, C, D may ha ve
been programmed for a variety of functions,
including panic (emergency) functions. For details,
see the Function Keys section.

20. INTERNAL SPEAKER: The built-in speaker

mimics the alarm sounder during alarms, and will
also "beep" during certain system functions. The
speaker also provides voice playback for any
recorded messages.