– 35 –
6FKHGXOLQJ

$ERXW6FKHGXOLQJ

The system provides up to 16 end-user schedules (programmable by master/installer
only), which can be used to control various types of events.
Each schedule causes a defined event to start and stop (when appropriate) at a
specified time.
Schedules can be set to automatically repeat a t various intervals.
Schedules can be set for random starting, if desired.

&UHDWLQJ6FKHGXOHV

1. + [#] + [6] [4]
(Master Code)
2. Enter a 2-digit schedule number from 01-16.
Press [] to continue. =
3. Enter the desired 2-digit event number from the
following list.
00 = clear the scheduled event
01 = turn a programmed output on or off
(see Using Device Commands section for a list of output device numbers used
in your system)
02 = set a user access schedule for one or more users
(see Security Codes section for an explanation of access groups)
03 = send a “latch-key” report to a pager if the system is no t disarmed by a specified
time; message sent is “777-7777.”
04 = automatically arm the system in STAY mode at a specified time
05 = automatically arm the system in AWAY mode at a specified time
06 = automatically disarm the system at a specified time
07 = Display the word “REMINDER” at a specified time
Press [] to continue.
4. For event number “01,” enter the output number
associated with this schedule.
Otherwise, this prompt is skipped.
Press [] to continue to the “Start” prompt belo w.