SYSTEM TROUBLE ERROR CODES

 

TBL Flashes /

READY

Trouble Condition

Action

 

 

Touchpad beeps

Flashes

 

 

 

 

 

 

6

NONE

Lost Key Mode

This is a reminder that the system has been put into the lost key mode ([STAY] &

 

 

 

 

[AWAY] pressed simultaneously). While in this mode, the system can only be dis-

 

 

 

 

armed with your EZ-IFOB. When you have replaced or re-keyed your deadbolt,

 

 

 

 

press [STAY] & [AWAY] simultaneously again to exit lost key mode.

 

 

7

NONE

Fire Zone Trouble

A problem has been detected with the Fire zone. Call for service.

 

 

 

 

 

 

 

 

1

1

Wireless Receiver TBL

A problem has been detected with the wireless receiver. Call for service.

 

 

 

 

or EZ Touchpad TBL

 

 

 

2

2

Wireless Receiver Jam

A problem has been detected with a wireless receiver. Call for service.

 

 

 

 

 

 

 

3

2-8

Wireless Transmitter

The battery in a wireless transmitter is low and should be replaced. This transmit-

 

 

 

Low Battery

ter is on the zone corresponding to the number of READY flashes. The replace-

 

 

 

 

ment battery for the GEM-TRANS2 door/window transmitter, GEM-PIR motion

 

 

 

 

detector and GEM-GB glass break detector is the Duracell DL123A 3 Volt Lithium

 

 

 

 

(2 required for the GEM-PIR and GEM-GB). The GEM-DT Dual Technology Sen-

 

 

 

 

sor requires 4 C cell Alkaline batteries. Warning: Replace batteries only with the same

 

 

 

 

type as specified above. Use of another battery may present a risk of fire or explosion. Do

 

 

 

 

not recharge or disassemble battery, or dispose of in fire.

 

 

 

 

 

 

 

4

2-8

Wireless Transmitter

A problem has been detected with a wireless transmitter on the zone correspond-

 

 

 

Supervisory Failure

ing to the number of READY flashes. Call for service.

 

 

 

 

 

 

 

 

5

1-4

Wireless Smoke

The battery in a wireless smoke detector is low and should be replaced.

The

 

 

 

Detector Low Battery

number of the smoke detector corresponds to the number READY flashes.

The

 

 

 

 

replacement battery is the Duracell MN1604 9 Volt Alkaline (2 required).

 

 

 

 

 

Warning: Replace batteries only with the same type as specified above. Use of another

 

 

 

 

battery may present a risk of fire or explosion. Do not recharge, disassemble, or dispose of

 

 

 

 

battery in a fire.

 

 

6

1-4

Wireless Smoke

A problem has been detected with a wireless smoke detector. Call for service.

 

 

 

 

Detector Supervisory

 

 

18

 

 

Failure

 

 

 

 

 

 

 

Page 18
Image 18