INDICATIONS AND PROBABLE CAUSES

Front Panel or Circuit Parameters Indicate Abnormal Operation

Connect a terminal or PC to the RS-232 (DB-9) craft interface, located on the faceplate. The ter- minal must be VT100 or compatible and set for 1.2 to 19.2 kbps, 8 data bits, no parity, 1 stop bit, and no flow control. Select “3” from the ADTRAN HDSL2 Main Menu Screen and “2” from the Span Status Screen:

Is signal quality fluctuating (this would occur when real-time mode is active)?

Is ATTEN (pulse attenuation) > 30 dB?

Are there any errors counting on the ES, SES, or UAS registers?

If the above conditions do not exist, the circuit should provide quality service; however, if any of the above conditions exist, cable problem or excessive loss situation is probable and more detailed cable testing should be done to verify all HDSL2 Loop Specifications are met. These conditions may also reflect intermittent cable faults or excessive noise impairments. If intermit- tent faults or noise impairments are suspected, select “5” from the HDSL2 Main Menu to review the Performance History Screen.

Front Panel Indications Under Normal Operation

DSL

Green

DSX

Green

ALM

Off

LBK

Off

Circuit Parameters Under Normal Operation

LOSS 30 dB

Good signal quality with no fluctuation

All HDSL2 Deployment Guidelines are met

HDSL2 DEPLOYMENT GUIDELINES

Cable pairs must be non-loaded

Total bridged tap < 2.5 kft

No single bridged tap > 2 kft

196 kHz insertion loss 35 dB

Pulse attenuation (loss on HDSL2 Span Status Screen) 30 dB

Maximum loop resistance is 900

Impulse noises < 50 dBrn as measured using a 50 kb filter

Wideband noise 31 dBrn as measured using a 50 kb filter

For more information regarding deployment guidelines and applications, reference ADTRAN’s Supplemental Deployment Information for HDSL/HDSL2, P/N 61221HDSLL1-10.

HDSL2 Loopback Control Codes

Name

Code

Comments

Arming (In-band)

11000

Signal sent in-band or over ESF data link. HDSL2 elements in disarmed

Arming (ESF)

0001 0010 1111 1111

state make transition to armed state. Detection of either code results in

 

(12 FF Hex)

Smartjack loopup, if NIU loopback is enabled.

Activation

1101 0011 1101 0011

Signal sent in-band. HDSL2 elements in armed state make transition to

(H2TU-C)

(D3D3 Hex)

loop-up state. Loop-up state timeout is programmable from the H2TU-C.

Activation

1100 0111 0100 0010

 

(H2TU-R)

(C742 Hex)

 

Deactivation

1001 0011 1001 0011

Signal sent in-band. HDSL2 element loopup state makes transition to

 

(9393 Hex)

armed state.

 

 

 

Disarming (In-band)

11100

Signal sent in-band or over ESF data link. HDSL2 elements in any state

Disarming (ESF)

0010 0100 1111 1111

make transition to disarmed state.

 

(24FF Hex)

 

Arming Time out

N/A

2 Hours

 

 

 

Loopup Time out

N/A

HDSL2 element in loopup makes transition to armed state.

 

 

Programmable from H2TU-C: None, 20, 60, or 120 minutes.

Loopback Time out

1101 0101 1101 0110

Signal sent in-band. Sets Loopback Timeout to NONE. Timeout will

Override

(D5D6 Hex)

return to previous value when pattern is removed. Arming pattern

 

 

(11000) must precede this pattern.

Span Power

0110 0111 0110 0111

Signal sent in-band. Disables span powering of remotes. Span power

Disable

(6767 Hex)

will return when pattern is removed. Arming pattern (11000) must

 

 

precede this pattern.