| Table 8. FT1 DP Product Specifications |
|
|
Loop Interface |
|
Modulation Type | 2B1Q |
Mode | Full Duplex, Echo Cancelling |
Number of Pairs | One |
Bit Rate | 784 kbps |
Baud Rate | 392K baud |
Service Range | Defined by Carrier Service Area Guidelines |
Loop Loss | 36 dB maximum @ 200 kHz |
Bridged Taps | Single taps < 2 kft, total taps < 2.5 kft |
Performance | Compliant with Bellcore |
Return Loss | 20 dB (40 kHz to 200 kHz) |
DSL Tx Signal Level | 13.5 dBm |
Input Impedance | 135Ω |
Return Loss | 20 dB (40 kHz to 200 kHz) |
DS1 Facility Interface
Fully compatible with Nortel
Power
Tested with the ADTRAN FT1 Repeater (P/N 1245211L1) and the ADTRAN FNID (P/N 1245201L1)
Total Power | |
| |
| |
FT1 DP Power Dissipation | 3.7 watts with FNID |
| 5.2 watts with FNID and FT1 Repeater |
| 6.1 watts with Local Power FNID and two FT1 Repeaters |
Span Power | 137 V or |
| Fusing 1.00 A (not |
|
|
Clock Sources |
|
Clock Sources | Internal, DS1 Derived |
Internal Clock Accuracy | ± 25 ppm, (exceeds Stratum 4). Meets T1.101 timing requirements. |
|
|
Tests |
|
Diagnostics | |
|
|
Mechanical |
|
Dimensions | 6.2" High, 1.1" Wide, 10.2" Deep, 16 ounces, nominal |
| Plugs into Nortel |
|
|
Environment | Operating (Standard): |
Temperature | |
Relative Humidity | Up to 95%, |
|
|
Part Number | 1245207L2 |
Section | 15 |