ADTRAN DE-4E specifications Pulse Attenuation

Models: DE-4E

1 19
Download 19 pages 17.21 Kb
Page 9
Image 9
Pulse Attenuation

The Current System Status Screen, illustrated in Figure 8, provides quick access to FT1 DP status information.

The Elapsed Time display indicates the period of time since the unit began collecting performance information. At each 15-minute interval, the performance information is transferred to the

15-minute performance data registers accessed from the Performance History screen. At each 24-hour interval, the performance data is transferred into the 24-hour performance data register also accessed using this screen.

Figure 8 consolidates current information for the DSL and DS1 interfaces. A key to the information provided is found in the center of the screen. Arrows indicate the key applies to the FT1 DP. The following defines terms used on this screen:

LOSS

Pulse Attenuation

 

Measurement

SYNC

DSL Loop 1 Sync Status

ES 15M/24H

Errored Seconds

SES 15M/24H

Severely Errored Seconds

UAS 15M/24H

Unavailable Seconds

NOTE

The first number is for the current 15-minute period. The second number is for the current 24-hour period.

A measure of signal quality for each DSL loop is graphically depicted on the bottom right and left of the screen. The measure is from 0 to 9 (poor to excellent signal quality). Guidelines for interpreting the indicators are:

0 ......... Poor signal quality. Noise margin is ≤ 0 dB

(≈ 10-7BER).

1-8 ...... Margin measurement above 10-7BER in dB.

9 ......... Excellent signal quality. Margin is ≥ 9 dB

above 10-7BER.

Predicting performance based upon signal quality varies with each loop. Generally, a noise margin of 0 dB or higher will support a bit error rate (BER) of better than 10-7.

Type “Z” at the Current System Status screen in order to reset performance registers to zero at both the Current System Status and Performance History screens.

FT1-DP

CURRENT SYSTEM STATUS

FNID

 

NETWORK

(DSL)

ELAPSED TIME 00:08:18

CUSTOMER

(DSL)

-----------------------

 

 

 

 

-------------------

00 dB

<-

 

LOSS

->

00 dB

 

NO

 

<-

 

SYNC

->

NO

 

000/00000

<-

ES

15M/24H ->

000/00000

000/00000

<-

SES

15M/24H ->

000/00000

498/00498

<-

UAS

15M/24H ->

498/00498

LOOPBACKS

INACTIVE

 

 

 

 

LOOPBACKS INACTIVE

FT1-DP SIGNAL

QUALITY

 

FNID DS1

FNID SIGNAL QUALITY

[ ]

9

--------------------

[ ]

9

[ ]

8

FRAME

——>

SF

[ ]

8

[ ]

7

CODE

 

——>

AMI

[ ]

7

[ ]

6

LBO

 

——>

0 dB

[ ]

6

[ ]

5

BPV

 

——>

00000

[ ]

5

[ ]

4

ES

 

——>

00000

[ ]

4

[ ]

3

SES

 

——>

00000

[ ]

3

[ ]

2

UAS

 

——>

00000

[ ]

2

[ ]

1

ALARMS

——>

NONE

[ ]

1

[ ]

0

NO SEALING CURRENT

[ ]

0

Press “Z” to zero registers, “M” for Main Menu.