Table 2. SW1 Option Settings

(Default settings are indicated in bold typeface.)

Switch

Function

Description

 

 

 

SW1-1

Code Select

SW1-1 On selects B8ZS line code. SW1-1 Off selects AMI.

 

 

Off

AMI

 

 

On

B8ZS

SW1-2

Framing

SW1-2 Off selects SF. SW1-2 On selects ESF.

 

 

Off

SF

 

 

On

ESF

SW1-3

Channel Select

Selects between Alternating and Contiguous DS0 channels.

 

 

Off

Alternate

 

 

On

Contiguous

SW1-4

Latching Loopback

Used to enable or disable latching loopbacks.

 

 

Off

Disabled

 

 

On

Enabled

SW1-5

Loopback Timeout

Used to enable or disable automatic loopback timeout.

 

 

Off

Automatic loopback timeout is disabled

 

 

On

Loopback timeout is enabled and set for 20 minutes.

SW1-6

Dumb/Smart Channel Bank Enable

Used to select dumb or smart channel bank operation

 

 

Off

Unit is provisioned for an NT1 bank with a Smart Transmit/Receive

 

 

 

Unit (STRU) installed. Two-state signaling available (smart mode)

 

 

On

Unit is provisioned for an NT1 bank with a Transmit/Receive

 

 

 

Unit (TRU) installed. Four-state signaling available (dumb mode)

SW1-8

Protected Loopback

Used to enable or disable protective loopback.

 

 

Off

Disabled.

 

 

On

Enabled.

 

 

 

 