Table 2. SW1 Option Settings
(Default settings are indicated in bold typeface.)
Switch | Function | Description | |
|
|
| |
Code Select | |||
|
| Off | AMI |
|
| On | B8ZS |
Framing | |||
|
| Off | SF |
|
| On | ESF |
Channel Select | Selects between Alternating and Contiguous DS0 channels. | ||
|
| Off | Alternate |
|
| On | Contiguous |
Latching Loopback | Used to enable or disable latching loopbacks. | ||
|
| Off | Disabled |
|
| On | Enabled |
Loopback Timeout | Used to enable or disable automatic loopback timeout. | ||
|
| Off | Automatic loopback timeout is disabled |
|
| On | Loopback timeout is enabled and set for 20 minutes. |
Dumb/Smart Channel Bank Enable | Used to select dumb or smart channel bank operation | ||
|
| Off | Unit is provisioned for an NT1 bank with a Smart Transmit/Receive |
|
|
| Unit (STRU) installed. |
|
| On | Unit is provisioned for an NT1 bank with a Transmit/Receive |
|
|
| Unit (TRU) installed. |
Protected Loopback | Used to enable or disable protective loopback. | ||
|
| Off | Disabled. |
|
| On | Enabled. |
|
|
|
|
Section | 3 |