DS3 MUX | JOBAID | |
| ||
| 0008 | |
|
|
DS3 MX
CLEI: M3CMSP0E_ _
DS3MX
1181020L1
POWER
STATUS
TEST
LOCKOUT
ON LINE
APS
TEST/
ENABLE
STATUS LEDs
POWER | ● OFF | No power is present on the unit |
| ● YELLOW | Unit is |
| ● GREEN | Unit is |
STATUS | ● OFF | Unit is |
| ● GREEN | DS3 signal is present and synchronized |
| ● RED | Local alarm or local and remote alarm condition detected |
| ● YELLOW | Remote alarm condition detected |
TEST | ● OFF | Unit is not in loopback |
| ● YELLOW | Loopback active |
LOCKOUT | ● OFF | APS enabled |
| ● YELLOW | APS disabled due to INHIBIT |
| ● RED | APS is locked out due to three |
|
| |
ONLINE | ● OFF | Unit is |
|
| transmit to network) |
| ● GREEN | Unit is |
APS PUSHBUTTON
■When depressed simultaneously with the Test/Enable switch on the
■When depressed with the Test/Enable switch on the
TEST/ENABLE BUTTON
■When depressed alone, tests all unit LEDs (multicolor LEDs appear YELLOW).
■When depressed simultaneously with the APS switch on the
INSTALLATION PROCEDURE
■Ensure the TA 3000 system chassis is properly mounted and wired for power. BNC Adapter Module, P/N 1181004L1, is required for DS3 operation. The adapter is mounted to connector J34 (J20 on 19” shelf), located in the lower right corner of the backplane.
■Ensure SCU is seated and receiving power.
■Plug DS3 module into slot A or B of system chassis. Gently but firmly push the DS3 Mux into one of the Mux slots, A or B, at the left end of the shelf. Simultaneous thumb pressure at the top (above the POWER LED) and bottom (below the Test/Enable button) of the unit will ensure a good seat of the DS3 pins into the backplane connector. Push the ejector tab up and closed against the DS3 faceplate.
■Allow the
PROVISIONING THE DS3 MULTIPLEXER
To provision the DS3 Mux, connect a terminal emulator via the
■At the LOGON screen, enter the system password. Note the default password is “PASSWORD” (case sensitive) and can be changed upon initial login.
■Select Common A or Common B from the Total Access Menu.
■Select option 2, Provisioning, and press <enter>.
The following table lists the provisioning settings and their default values.
Options | Settings | Default |
Framing | M13, | Auto detect |
Line Build Out | Short, Long | Short |
Clock Source | Local, Loop | Loop |
Service State | In Service, | |
Linked Provisioning | Enabled, Disabled | Enabled |
Line Code | B3ZS (cannot be changed) | B3ZS |
■Framing - sets the DS3 framing.
■Line Build Out - set LBO to either Short or Long.
Short - cable length is less than 225 feet of 734A or equivalent coaxial cable or less than 100 feet of Lucent 735 or equivalent coaxial cable.
Long - cable length is greater than 225 feet of 734A or equivalent coaxial cable or greater than 100 feet of Lucent 735 or equivalent coaxial cable.
■Clock Source - selects where the transmit clock derives its timing. Local - derives its clock from an
Loop - derives its clock from the incoming DS3 data stream.
■Service States - the following table lists the operations allowed in each state.
Service | Report | Report | Switch to | Allow | Trib | Ntwrk | Allow | Allow | Allow |
State | Alarms | TL1 PM | Provide | Forced | Data | Data | Dwnld | Prov | Maint |
|
| Data | Service | Switch |
|
|
|
|
|
|
|
| on Fault | into Unit |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
OOS, Un | N | Y | N | N | AIS | IDLE | Y | Y | Y |
OOS, Ma | N | Y | Y | Y | Norm | Norm | Y | Y | Y |
In Service | Y | Y | Y | Y | Norm | Norm | N | N | N |
■Linked Provisioning - when enabled, automatically transfers provisioning changes made to the enabled unit to the other unit.
■Line Code - this value is hardcoded to B3ZS and cannot be changed.
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED. | ■ For a complete Installation and Maintenance: 877.457.5007, Document #317. Please have your fax number available. ■ |