Product Features

Compatible with 2B1Q basic rate services and standard ISDN terminals

Provides 2B+D basic rate service

Conforms to ANSI T1.601- 1992 and ANSI T1.605-1991

Supports multiple switch vendors Lucent 5ESS, NTI DMS-100, Siemens EWSD, NEC, and National ISDN-1

Responds to Quiet Mode and Insertion Loss Test

Provides automatic overcurrent protection for S/T power

Selectable terminating impedance; 50 Ohm,

100 Ohm, or unterminated

The ADTRAN® NT1 ACEprovides the network termination for 2B1Q ISDN basic

rate service. The NT1 ACE provides a 2B+D basic rate interface between the subscriber’s terminal equipment and the ISDN network. Basic rate ISDN consists of two 64 kbps B channels and a single 16 kbps D channel. Connection to the ISDN network is made with a U interface. Connection to the subscriber’s terminal equipment is by an S/T interface. The U and the S/T interfaces conform to ANSI and CCITT standards and perform all Layer 1 functions.

The NT1 ACE is designed with aesthetics as well as functionality in mind. The unit is enclosed in an attractive, durable plastic housing appropriate for desk-top use. The NT1 ACE is powered by the wall-mount power supply included with the unit. The wall-mount power supply provides up to 8.9 W of power for terminal equipment. The NT1 ACE monitors

the S/T interface for overcurrent fault condi- tions. In the event of such a condition, the unit automatically limits the amount of delivered current until the fault condition is removed.

As many as eight passive bus devices may be connected to the S/T interface of the NT1. These connections can be in one of the following two modes: multiple terminals within 50 meters of each other over the full 1,500 meter range of the interface, or multiple termi- nals of arbitrary spacing within 200 meters. Also, termination impedance options include

50 Ohm, 100 Ohm, or unterminated. The NT1 ACE is protected from lightning and harmful line transients on the network interface.

Three LED status indicators on the NT1 ACE aid in fault isolation. Indicators display the status for Power, Network Ready, Network and Customer Errors.

Provides U-interface lightning protection

Standard five-year warranty

Telephone

 

 

 

 

Company Office

 

Customer Premises

 

 

 

 

ISDN

U-Interface

ERROR

NT1 ACE

S/T

Switch

 

READY

 

Local Loop

POWER

 

BUS

Video-

Conference

Equipment

NT1 ACE

ISDN Phone

Page 1
Image 1
ADTRAN NT1 ACE warranty