7.0 SPECIFICATIONS

LOOP INTERFACE:

 

Line:

2-Wire (TIP and RING)

Operating Mode:

Full-duplex

Data Rate:

160 kbps total; 144 kbps available to customer

Signal Format:

2B1Q

Output Amplitude:

2.5 V, zero-to-peak

Tx Source Impedance:

As per ANSI T1.601

Rx Source Impedance:

As per ANSI T1.601

Receiver Sensitivity:

As per ANSI T1.601

CUSTOMER INTERFACE:

 

Line:

4-Wire (Tx and Rx pair)

Operating Mode:

Full-duplex

Data Rate:

192 kbps total; 144 kbps available to customer

Signal Format:

Alternate Mark Inversion, 100% duty cycle

Output Amplitude:

.75 V, zero-to-peak

Tx Source Impedance:

As per ANSI T1.605

Rx Source Impedance:

As per ANSI T1.605

Receiver Sensitivity:

As per ANSI T1.605

MECHANICAL:

 

Size:

5.625” H x 6” D x 1.375” W

Weight:

10 oz.

Mounting:

Mounts in Type 400 equipment shelves

POWER:

On-Card Dissipation

NT1 Type 400 Standalone:

115 VAC Internal Power Supply

 

60 Hz, .07 amps

 

Sources S/T Power to 7W

NT1 T400 Circuit Pack:

-48 VDC

 

1.1 Watt Maximum On-Card Dissipation

 

Sources S/T Power to 12W

ENVIRONMENTAL:

 

Temperature:

Operating 0 to +50 °C

 

Storage -20 to +70 °C

Relative Humidity:

Up to 95%, noncondensing

61212016L1-1

NT1 T400 User Manual

7

Page 16
Image 16
ADTRAN NT1 T400 user manual Specifications, Loop Interface