6

 

 

 

 

 

 

 

 

 

1. LTU

 

 

 

 

 

SHDSL Version

 

Main

 

 

 

 

 

Vendor List Number

1. Unit Information

 

 

 

 

 

Menu

2. NTU

 

 

 

 

 

Vendor Issue Number

 

 

1. Data Mode = E1, Timeslots

 

 

 

Vendor Software Version

 

1. Unit Options

 

 

1. Data Type = E1

Unit Identification Code (CLEI)

 

2. Local Management = Enabled

 

1. Disabled

2. Data Rate = 3

Vendor ID

 

 

 

 

 

 

 

 

Vendor Model Number

 

 

 

 

1. Internal

2. Enabled

3. Apply Settings

 

 

3. Clock Source = Internal

Vendor Serial Number

 

 

2. External

 

 

Manufacture Date

 

 

 

 

 

1. In Service

 

 

 

 

4. Service State = In Service

 

 

PROM Check Sum

 

 

 

2. Out of Service - Unassigned

 

 

 

 

1. Disabled

 

 

 

 

5. Ext Port Alarms = Enabled

3. Out of Service - Maintenance

 

 

 

 

2. Enabled

 

 

 

 

 

 

SHDSL Version

 

 

 

6. Circuit ID

 

 

 

 

 

 

 

 

 

 

 

 

 

7. Restore Factory Defaults

1.-255. CVCs to cause a SES

 

Vendor List Number

 

 

 

Vendor Issue Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8. Upgrade Firmware

 

0. Disabled

 

Vendor Software Version

 

2. Provisioning

9. Change Password

 

1-15. Threshold in dB

 

Unit Identification Code (CLEI)

 

 

 

Vendor ID

 

 

 

 

 

 

 

 

 

 

 

 

 

0. Disabled

 

 

 

 

1. SES Count Threshold = 50 CVCs

 

Vendor Model Number

 

2. SHDSL Options

1-127. Threshold in dB

Vendor Serial Number

 

2. SNR Margin Alarm Threshold = Disabled

 

 

 

0. Disabled

Other Vendor Information

 

 

 

 

 

 

 

 

3. Loop Attenuation Alarm Threshold = Disabled

 

 

 

 

 

 

1-900. Seconds

 

 

 

 

4. ES 15 Minute Alarm Threshold = Disabled

 

 

 

 

 

 

 

 

 

 

 

5. SES 15 Minute Alarm Threshold = Disabled

 

1. Line Coding = HDB3

1. AMI

 

 

 

 

2. HDB3

 

Issue

 

6. UAS 15 Minute Alarm Threshold = Disabled

 

 

1. Unframed

 

 

 

 

 

0. Disabled

 

 

 

 

7. CVC 15 Minute Alarm Threshold = Disabled

2. Framing Mode = CCS

 

2. CCS

 

1-65535. Errors

 

 

3. CCS w/CRCA

 

 

 

 

 

 

1,

 

8. LOSWS 15 Minute Alarm Threshold = Disabled

 

 

 

 

 

 

 

 

 

 

 

August

1. E1 Options

 

 

 

 

 

1. Disabled

3.

 

 

 

 

3. ISDN-PRA V3 = Disabled

 

1. DSX-1 Line Buildout

1. 0-133 Feet

 

2. Enabled

 

2. 133-266 Feet

4. Idle Pattern = FFh

 

 

 

 

 

 

 

 

 

 

3. 266-399 Feet

 

 

 

2003

2. T1 Options

 

 

 

 

 

 

1. AMI

4. 399-533 Feet

 

General Status

 

2. Line Coding

 

 

2. HDB3

5. 533-655 Feet

 

Aggregate Rate (kbps)

 

 

 

 

 

 

SNR Margin (dB) (Cur/Min/Max)

 

 

 

 

1. Unframed

 

 

 

 

3. Framing Mode

 

 

 

Loop Attenuation (dB) (Cur/Min/Max)

 

 

 

2. SF

 

 

Errored Seconds (ES)

 

 

 

 

 

 

 

 

4. Idle Pattern

 

3. ESF

 

 

Severely Errored Seconds (SES)

 

 

 

1. Disabled

 

 

Unavailable Seconds (UAS)

 

 

 

 

0. Disabled

 

 

 

5. FDL Monitoring

 

 

Code Violations Count (CVC)

 

 

 

 

 

 

 

2. Enabled

 

 

 

 

 

 

 

1-999. Timeout in Minutes

LOSW Seconds (LOSWS)

 

 

1. Loopback Time Out = Disabled

 

 

 

Loopback Status

 

4. Test Options

 

 

 

BERT Status

 

2. BERT Pattern = 2e15-1

 

1. ALT

 

 

 

 

 

 

2. 2047

 

 

 

 

 

 

 

1. Normal

General Status

 

 

 

3. BERT Pattern Polarity = Normal

3. 2e15-1

 

 

 

2. Inverted

Data Rate

 

 

 

 

 

 

4. QRSS

 

 

 

1. SHDSL = ALARMS

 

 

Framing Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Status

 

 

 

 

Errored Seconds (ES)

 

 

2. E1 = ALARMS

 

 

 

 

 

 

 

 

 

 

Severely Errored Seconds (SES)

 

 

 

 

 

 

 

1. Local Loopback

 

1. Dual Sided

 

 

Unavailable Seconds (UAS)

 

 

 

 

 

 

Code Violations Count (CVC)

 

 

4. Test

 

2. Customer

 

 

 

 

 

 

 

Transmit Customer Alarm Indication Signal (Tx Cust AIS)

 

2. Remote Loopback

 

3. Network

 

 

 

3. BERT

 

 

 

Transmit Network Alarm Indication Signal (Tx Net AIS)

 

 

 

 

 

61182210L1-5A

1. SHDSL

4. Off

 

 

Customer Source Address Bits (Cust SA -Bits)

5. Performance History

 

 

2. E1

 

 

 

Network Source Address Bits (Net SAS-Bits)

 

 

 

 

Network Address Bit (Net A-Bit)

6. Terminal Mode

 

 

 

 

 

 

 

 

 

 

 

 

Figure 3. SHDSL T1/E1 LTU Menu Tree

 

 

Page 6
Image 6
ADTRAN SHDSL T1 specifications Shdsl T1/E1 LTU Menu Tree