4. PROVISIONING

4. PROVISIONING

All provisioning will be handled through the SCU communication link, either through the menu access or SNMP. There are no onboard DIP switches or jumpers. The unit will retain provisioning data in a nonvolatile memory device in case of a loss of power to the module.

Total Access 3000 system management and provi- sioning is facilitated by a series of intuitive menus that are accessible on a computer screen. Connecting either a VT100 terminal or a PC emulating a VT100 terminal to the craft interface on the SCU front panel allows access to the menus and management features of the Total Access 3000.

The front craft access port for the Total Access 3000 system is located on the front panel of the SCU and is a DB-9 connector. Access can also be made to the Total Access 3000 chassis from the backplane through the port labeled ADMIN (J31). It is a DB-25 connector, and is located on the upper right corner of the backplane.

NOTE

Connecting to the Total Access 3000 chassis from the front craft port on the SCU requires a straight serial data cable. Connection to the Total Access 3000 chassis via the rear connector on the backplane requires the use of a null modem cable, because that port is configured for a modem and expects to see DCE equipment.

The parameters of the VT100 terminal should be set as follows:

9600 Baud

No parity

8 Data bits

1 Stop bits

No Flow Control

Windows HyperTerminal

Windows HyperTerminal can be used as a VT100 terminal emulation program. Open HyperTerminal by selecting Programs/Accessories/HyperTerminal. Refer to the Help section of HyperTerminal for additional information.

NOTE

To ensure proper display background, select VT100 terminal emulation under Settings.

Password and User ID

Password protection is factory enabled. If password protection is enabled, the SCU will display the logon screen, and a valid account name and password are required to access menus. The factory default account names and default passwords (both are case sensitive) are displayed in Table 3.

Table 3. Account Names and Passwords

Account

Default

Access

Name

Password

Rights

 

 

 

ADMIN

PASSWORD

Administration Access

 

 

 

READONLY

PASSWORD

Read Access only

 

 

 

READWRITE

PASSWORD

Read and Write

 

 

Access

 

 

 

TEST

PASSWORD

Read and Test Access

 

 

 

NOTE

The Account Name and Password are to be entered in all capital letters.

Menu Navigation

The following subsection describes the SHDSL T1/E1 LTU menus. Most menu selections are made by typing the corresponding number and then pressing ENTER. If the wrong selection is made, pressing ESC will display the previous screen. The Question Mark (?) can be used at any time to display a list of menu commands.

Main Menu

The Total Access Main menu allows the user to access the module for various functions such as provisioning, status, alarms, and performance monitoring.

The menu tree in Figure 3 illustrates the path to every provisioning, performance, and test access point in the SHDSL T1/E1 menu system.

Table 4 lists the complete set of configurable options with settings and factory default values.