Table 6. T1 Port Statistics Definitions
Statistic | Framing Mode | Definition |
|
|
|
Errored Seconds (ES) | Unframed | LOS condition or BPV’s > 0 |
|
|
|
| SF | LOS or LOF condition, or if BPV’s > 0 or FE’s > 0 |
|
|
|
| ESF | LOS or LOF condition, or if BPV’s > 0 or FE’s > 0 |
|
|
|
Severely Errored Seconds (SVS) | Unframed | LOS condition or BPV’s > 1544 |
|
|
|
| SF | LOS or LOF condition, or if BPV’s > 1544 or if FE’s > 8 |
|
|
|
| ESF | LOS or LOF condition, or if BPV’s > 1544 or if FE’s > 8 |
|
|
|
Unavailable Seconds (UAV) | N/A | If 10 continuous SES’s, then UAS |
|
| If 10 continuous seconds with no SES’s, then no UAS |
|
|
|
Code Violations Count (CVC) | Unframed | If BPV’s > 0 |
|
|
|
| SF | If BPV’s > 0 or FE’s > 0 |
|
|
|
| ESF | If BPV’s > 0 or FE’s > 0 |
|
|
|
6. MAINTENANCE
The SHDSL T1/E1 LTU requires no routine mainte- nance for normal operation.
ADTRAN does not recommend that repairs be attempted in the field. Repair services may be obtained by returning the defective unit to ADTRAN. Refer to the Warranty and Customer Service section for further information.
7. SPECIFICATIONS
Specifications for the Total Access 3000 SHDSL T1/E1 LTU are detailed in Table 7.
8.WARRANTY AND CUSTOMER SERVICE
ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifi- cations or fails while in service. Warranty information can be found at www.adtran.com/warranty.
Table 7. SHDSL T1/E1 LTU Specifications
Environmental
Operating Temperature:
Storage Temperature: | |
Relative Humidity: | 90 percent maximum @ |
| 50°C, noncondensing |
Maximum Current Draw: | 0.15 A maximum |
| @ Ð48 VDC |
Maximum Heat | 3.5 watts |
Dissipation: |
|
Physical
Dimensions: | 6 in. H x .625 in. W x 10 |
| in. D |
Weight: | < 1 lb. |
| |
|
|
Part Number | |
|
|
SHDSL T1/E1 LTU | 1182210L1 |
Module: |
|
|
|
Issue 1, August 2003 | 9 |