8. MAINTENANCE
The T200
ADTRAN does not recommend that repairs be attempted in the field. Repair services may be obtained by returning the defective unit to ADTRAN. Refer to the Warranty and Customer Service section for further information.
9. SPECIFICATIONS
Specifications for the T200
10.WARRANTY AND CUSTOMER SERVICE
ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifi- cations or fails while in service. Warranty information can be found at www.adtran.com/warranty.
U.S. and Canada customers can also receive a copy of the warranty via ADTRAN’s
•Request document 414 for the U.S. and Canada Carrier Networks Equipment Warranty.
•Request document 901 for the U.S. and Canada Enterprise Networks Equipment Warranty.
Refer to the following subsections for sales, support, CAPS requests, or further information.
ADTRAN Sales Pricing/Availability:
ADTRAN Technical Support
Standard hours: Monday - Friday, 7 a.m. - 7 p.m. CST
Emergency hours: 7 days/week, 24 hours/day
ADTRAN Repair/CAPS Return for Repair/Upgrade: (256)
Repair and Return Address
Contact Customer and Product Service (CAPS) prior to returning equipment to ADTRAN.
ADTRAN, Inc. CAPS Department
901 Explorer Boulevard Huntsville, Alabama
Table 9. Troubleshooting Guide
Condition: All front panel indicators are off.
Solutions:
1.Make sure the
2.Verify that the enclosure is delivering sufficient voltage to the unit.
If steps 1 and 2 pass and front panel indicators remain off, replace the
Condition: DSL 1/DSL 2 LED is red.
Solutions:
1.Verify that loss (attenuation) on Detailed System Status screen is < 32 dB on the first segment of the circuit and < 28 dB on the second and third segments of the circuit.
2.Verify that the loop meets requirement stated in the HDSL4 Deployment Guidelines section of this practice.
3.Verify that noise on the HDSL4 loops is within acceptable limits.
If steps