AEG 54840 manual Water inlet filter, Emergency emptying out

Models: 54840

1 44
Download 44 pages 35.27 Kb
Page 28
Image 28

28Care and cleaning

Water inlet filter

If you notice that the machine is taking longer to fill, check that the filter in the water inlet hose is not blocked.

1.Turn off the water tap.

2. Unscrew the hose from the tap.

3. Clean the filter in the hose with a stiff brush.

4. Screw the hose back onto the tap.

Emergency emptying out

If the water is not discharged, proceed as follows to empty out the machine:

1.pull out the plug from the power socket;

2.close the water tap;

3.if necessary, wait until the water has cooled down;

4.open the pump door;

5.place a bowl on the floor and place the end of the emergency emptying hose into the bowl. Remove its cap. The water should drain by gravity into the bowl. When the bowl is full, put the cap back on the hose. Empty the bowl. Repeat the procedure until water stops flowing out;

6.clean the pump if necessary as previously described;

7.replace the emergency emptying hose in its seat after having plugged it;

8.screw the pump again and close the door.

Page 28
Image 28
AEG 54840 manual Water inlet filter, Emergency emptying out