Instructions for the Installer

Engineer technical data

OVERALL DIMENSIONS

Width:

580 mm.

 

Depth:

510 mm.

 

Height:

88 mm.

 

Weight:

8 Kg.

CUT OUT DIMENSIONS

Width:

550 mm.

 

Depth:

470 mm.

 

Thickness:

30 mm.

SUPPLY CONNECTIONS

Gas:

 

 

RC 1/2 inch (1/2 inch male) Rear right hand corner

 

Electric:

 

 

230-240V 50Hz supply, 3 core flexible cable with

 

non rewireable plug fitted with a 3 amp cartridge fuse.

IGNITION HT SPARK

Spark Generator

 

Ispra Control's BF 50046 - 230-240V 0.6 YA T120

HEAT INPUT

Spark Gap : Fixed

 

 

Rear Left Burner

1.9 kW (6483 BTU/HR)

(semi rapid)

 

 

Front Left Burner

2.9 kW Natural Gas (9895 BTU/HR)

(rapid)

2.7 kW L.P.G. (9212 BTU/HR)

Rear Right Burner

1.9 kW (6483 BTU/HR)

(semi rapid)

 

 

Front Right Burner

1.0 kW (3412 BTU/HR)

(auxiliary)

 

 

APPLIANCE CLASS

3

 

APPLIANCE CATEGORY

II2H3+

 

GAS SUPPLY

Natural gas G20 / 20mbar

12

Page 12
Image 12
AEG 84602 G, 85600 G, 856001 G manual Instructions for the Installer, Engineer technical data